Fanuc FOCAS

Use this dialog to configure Fanuc FOCAS monitoring

param

Enable Fanuc FOCAS monitor

Check this field to enable the Fanuc FOCAS monitoring.

param

Host/Addr:

Use this field to specify the CNC host name or IP address.

param

Ping before connecting

Check this field to limit the TCP/IP connection load by pinging the device before attempting to open the COM port.

If the device does not respond to a ping message no attempt is made to open the port.

param

Log message when port starts

Check this field to generate a message when the port starts.

param

CNC Type

param

Cycle On

Use this field to specify the message generated when the cycle is on.

param

Cycle Off

Use this field to specify the message generated when the cycle is off.

param

Alarm On;

Use this field to specify the message generated when the control goes into alarm.

param

Alarm Off

Use this field to specify the message generated when alarm stops.

param

Feed hold On

Use this field to specify the message generated when feed hold on.

Feed hold includes single step etc.

param

Feed hold Off

Use this field to specify the message generated when feed hold is off.

Feed hold includes single step etc.

param

Program changed

Use this field to specify the message generated when program changed.

param

M30 Counter #1

Use this field to specify the message generated when M30 Counter #1 changes

param

M30 Counter #2

Use this field to specify the message generated when M30 Counter #2 changes

Overrides

Spindle speed

Feed rate

Rapid feed

param

Enable control modes

Check this field to enable control modes.

param

Panel Option

Macros

param

Enable Macro 1

param

Macro

param

Check for change

param

Val.1

param

Message val.1

param

Val.2

param

Message val.2

PMC

param

PMC Variables

param

PMC Address

param

Bit

param

Data Type

param

On

param

Off

Additional

param

Notify change of Work Zero Offset

param

Message