Object types

Backup dialog

Object type

param

Object type

Use this field to specify the object type.

param

Extension

Check this field to specify the extension. Always specify extensions for job object types, unless a separate object directory is specified for each job object. I.e. If $DATA is the default directory for one or more job objects, you must specify an extension.

Object settings

param

Object is a job

Check this field if this object is a job. Job objects are transferred to/and from separate directories, and can contain multiple files.

param

Send from job directory

Check this field if DNC-Max should try to locate the requested file in one of the job directories, before it scans the objects default directory.

param

Replace if found in job directory

Check this field if DNC-Max should try to locate the received file in one of the job directories, and replace the first file found. If no file is found in any of the job directories, the received file is save in the objects default directory or $INCOMING, depending on the setting of 'Always save files in $INCOMING' on the 'Port settings' setup sheet.

param

Directory name

Use this field to specify where programs matching this set should be saved. If path information is included in the auto received program, that information could overwrite the information specified here. To configure how path information should be handled, please go to the 'Path' setup sheet for this set.

param

Real name

This field shows the actual path used, with any environment variables expanded.