CIMCO Software 7 Releases

CIMCO Software 7.55.68 PreviewReleased: 14-11-16Register to download
Changes since previous version:
CIMCO DNC-Max 7.55.68
  • FTP Server Port: Improved responses. Welcome message is now only 1 line.
CIMCO Software 7.55.67 PreviewReleased: 29-09-16Register to download
Changes since previous version:
CIMCO DNC-Max 7.55.67
  • Fixed an issue where failed auto imports with import queue turned on would leave empty temporary files behind, eventually blocking further import queue usage.
CIMCO Software 7.55.66 PreviewReleased: 09-09-16Register to download
Changes since previous version:
CIMCO NC-Base 7.55.66
  • Fixed Cimco Edit hanging when double clicking associated file.
CIMCO Software 7.55.65 PreviewReleased: 05-09-16Register to download
Changes since previous version:
CIMCO Edit 7.55.65
  • Fixed a number of issues when editing files with percentage (%) in the filename.
CIMCO NC-Base 7.55.65
  • Fixed not creating backup when closing editor frame with 'x' and choosing to save file.
CIMCO Software 7.55.64 PreviewReleased: 29-08-16Register to download
Changes since previous version:
CIMCO DNC-Max 7.55.64
  • Mazak Serial Protocol: Cleaned up behavior of the options to use comments as filenames.
CIMCO Software 7.55.63 PreviewReleased: 08-08-16Register to download
Changes since previous version:
CIMCO Edit 7.55.63
  • Fixed issue with closing file compare window when windows are not default maximized.
  • It is no longer possible to change filters during simulation.
CIMCO DNC-Max 7.55.63
  • Fixed issue where Heidenhain FE serial protocol would not check serial data for barcode or DPRNT messages.
CIMCO NC-Base 7.55.63
  • NC-Base client is now able to create a backup before and after manual editing. This improves versioning of files when using DNC-Max directory monitoring.
CIMCO Software 7.55.61 PreviewReleased: 24-06-16Register to download
Changes since previous version:
CIMCO DNC-Max 7.55.61
  • Korean translations updated.
CIMCO MDC-Max 7.55.61
  • Fixed full screen on multiple displays.
  • Fixed Chinese characters in pie charts and multi bars graphs.
CIMCO Software 7.55.60 PreviewReleased: 15-06-16Register to download
Changes since previous version:
CIMCO MDC-Max 7.55.60
  • Fixed MDC Export Configuration dialogs with wrong defaults.
  • Fixed override configuration in the NETLink / S7 protocol.
  • Added support for reading of spindle override in NETLink / S7 protocol.
  • Updated override configuration in Heidenhain, Focas, MTConnect, NETLink protocols.
  • Added customer stop tag values in MTConnect protocol.
  • Web Client: Fixed job file format when both ';' and ',' was present in job file.
CIMCO NC-Base 7.55.60
  • Fixed problem with incorrectly versioned programs when secure mode is enabled.
CIMCO Software 7.55.59 PreviewReleased: 31-05-16Register to download
Changes since previous version:
CIMCO Edit 7.55.59
  • Updated Mazatrol viewer.
  • Updated Okuma and Mazak ISO filters: Arc movements and detection improved.
  • Updated Fanuc and Siemens filters.
CIMCO DNC-Max 7.55.59
  • Network protocol: Auto generated report should not be auto deleted anymore.
CIMCO Software 7.55.58 PreviewReleased: 20-05-16Register to download
Changes since previous version:
CIMCO MDC-Max 7.55.58
  • Web Client: Fixed error in backdating where wrong machine number was used.
CIMCO Software 7.55.57 PreviewReleased: 20-05-16Register to download
Changes since previous version:
CIMCO Edit 7.55.57
  • Mazak ISO filter updated.
  • Fanuc filter updated, fixed issue with G98 and G99 cycles.
CIMCO MDC-Max 7.55.57
  • MDC Web Client now supports backdating.
  • Fixed issue with empty error messages during MDC first run.
CIMCO Software 7.55.56 PreviewReleased: 29-04-16Register to download
Changes since previous version:
CIMCO Edit 7.55.56
  • Heidenhain filter updated: Fixed issue with Q218.
  • Fixed issue where user could not save hidden file.
  • Filtype drop down menu now auto sizes.
  • Added Willemin filter.
CIMCO MDC-Max 7.55.56
  • Fixed issue with inconsistency of MDC cache.
  • Fixed issue with daylight saving time.
  • Fixed canceling of running report.
CIMCO Software 7.55.55 PreviewReleased: 12-04-16Register to download
Changes since previous version:
CIMCO Edit 7.55.55
  • Updated German translation.
  • Fixed label error in advanced renumbering (beta) feature.
CIMCO DNC-Max 7.55.55
  • Updated German translation.
CIMCO NC-Base 7.55.55
  • The "Clear" button in the search panel now correctly clears machine selection.
  • File notes is now visible for programs on the import queue.
  • Fixed crash when renaming associated files.
CIMCO Software 7.55.54 PreviewReleased: 05-04-16Register to download
Changes since previous version:
CIMCO Edit 7.55.54
  • Mazak Viewer updated: Fixed missing character with T+.
CIMCO MDC-Max 7.55.54
  • Fixed problem with operator screen layout.
CIMCO Software 7.55.53 PreviewReleased: 30-03-16Register to download
Changes since previous version:
CIMCO Edit 7.55.53
  • Mazak Viewer updated: Improved T+ .
CIMCO MDC-Max 7.55.53
  • HTML reports converted to PDF using wkhtmltopdf.exe when it is installed in CIMCO\MDCMax\Sys
  • Fixed export of timeline to Excel
  • Setup sheet Machine/Groups moved to Report Setup tab
  • Added backward compatibility for XML export (New XML Setup sheet in Report Setup tab)
  • Added a new MDC protocol for NetLink (based on libnodave) – extended features
  • Added charts types in Report Setup
  • Removed switching between pie chart and bar chart (in some cases incompatible presentation of data)
  • Fixed live pie charts
  • Fixed last selected report in Report Setup tab
  • Fixed last selected screen in Live Setup tab
CIMCO Software 7.55.52 PreviewReleased: 23-03-16Register to download
Changes since previous version:
CIMCO Edit 7.55.52
  • Mazak Viewer updated: Improved Mazak Smart and T+ .
  • Heidenhain filter updated: Fixed bug with sign before Q variables.
CIMCO DNC-Max 7.55.52
  • Network Protocol: Fixed issue when sending local file using rename trigger.
CIMCO NC-Base 7.55.52
  • Added the option to keep status' from auto updating when program file is modified.
  • Heidenhain filter updated: Fixed bug with sign before Q variables.
CIMCO Software 7.55.51 PreviewReleased: 14-03-16Register to download
Changes since previous version:
CIMCO CNC-Calc 7.55.51
  • New Icons created for turning operations.
  • New Conctant Cut Turning Operation: The new operation type Constant Cut has been developed in CNC-Calc. This is a roughing operation with the option for one finish path with a given depth. The operation will try to maintain a constant load on the tool and by doing so it will extend the lifetime for the tools with up to 30%. Please notice that Lollipop tools are the only tools supported by this operation type.
CIMCO DNC-Max 7.55.51
  • Network Protocol: When sending files, it is now possible to rename the file, using a trigger, and replace the triggered part with user defined input. Can be found under Advanced->Protocol.
CIMCO MDC-Max 7.55.51
  • Fixed problem with timeline that does not refresh when slide show is running.
CIMCO NC-Base 7.55.51
  • File notes information is now stored so previous file notes can still be seen.
CIMCO Software 7.55.50 PreviewReleased: 26-02-16Register to download
Changes since previous version:
CIMCO Edit 7.55.50
  • Updated portuguese translation.
CIMCO DNC-Max 7.55.50
  • Updated portuguese translation.
  • Fixed issue when auto receiving a directory with main program file and associated files while using import queue.
CIMCO MDC-Max 7.55.50
  • Fix bug where popup screens may popup multiple times.
  • Respect setting "Auto close subscreen when button pushed".
CIMCO Software 7.55.49 PreviewReleased: 18-02-16Register to download
Changes since previous version:
CIMCO Edit 7.55.49
  • Fixed issue where file note window would not close if no file note existed for selected program.
  • Backplot is no longer disabled when running the editor in NC-Base minimal or superminimal mode. If the backplot should be disabled, disable the plugin in Editor configuration -> Plugins -> Deactivate Backplot.
  • Fixed issue in NC-Base client where you could not view file changes before changing selection in log.
  • Fixed editor crashes when loading PDF in NC-Base preview pane.
CIMCO Software 7.55.48 PreviewReleased: 15-02-16Register to download
Changes since previous version:
CIMCO DNC-Max 7.55.48
  • FTP Server port: Fixed issue with "CWD .." command. Now handled as "CDUP".
  • Fixed error with auto receiving associated programs not being able to find main program.
  • When keeping NC-Base directory when sending files the $NCBASEDIR variable is automatically used now. Before the $DATA was used.
CIMCO MDC-Max 7.55.48
  • Fixed incorrect encoding format in exported XML file in MDC client UTF-8 -> ISO-8859-1.
  • Fixed automatic events in back-dating engine.
  • Added time line legend to HTML report.
  • Fixed problem with printing of HTML reports
CIMCO Software 7.55.47 PreviewReleased: 09-02-16Register to download
Changes since previous version:
CIMCO MDC-Max 7.55.47
  • MDC Operator screen: Button font size and job list font size can now be configured individually.
CIMCO Software 7.55.46 PreviewReleased: 04-02-16Register to download
Changes since previous version:
CIMCO CNC-Calc 7.55.46
  • Constant cut has been split in two individual operations.
  • Constant Cut Inside-Out: Works like the original Pocket Milling Operation.
  • Constant Cut Outside-In: Works like the original Constant Cut.
  • The Constant Cut Inside-Out works like the Pocket Operation but the actual toolpaths are laid out as constant cut toolpaths
CIMCO DNC-Max 7.55.46
  • Network Protocol: Report failure request standard template updated.
  • DNC-Max Client: Only one client per computer can be opened as default. Use command line /newwin to force the DNC-Max client to open additional instances.
CIMCO MDC-Max 7.55.46
  • MDC-Max Operator screen: It is now possible to save input value and evaluated output values as an environment variable. These variables are local for each client, and can be used when executing external command using a button.
  • Added new option to execute target file, in button external command, with windows default application.
  • Now possible to hide output value from operator screen. This is useful if an environment variable is needed but the value should not be shown.
  • Now possible to increase the size of Input fields and Show Value fields.
CIMCO Software 7.55.45 PreviewReleased: 28-01-16Register to download
Changes since previous version:
CIMCO Edit 7.55.45
  • Updated Finnish translations.
  • Fixed blinking "Rotate View" button when using solid animation in backplot.
  • Added new Heidenhain Universal filter for backplot. This filter will automatically detect if the file is Heidenhain ISO or Heidenhain cycles and use the corresponding filter to simulate.
CIMCO DNC-Max 7.55.45
  • Updated Finnish translations.
  • Network Protocol: Fixed issue where auto generated report was deleted when any changed was detected by directory monitor.
  • Serial Protocol port: Fixed crash when trying to export received program with no name.
  • Terminal Port: If monitor message is received but is not a match for the defined messages in the DNC-Max server, the message is ignored.
CIMCO Software 7.55.44 PreviewReleased: 19-01-16Register to download
Changes since previous version:
CIMCO Edit 7.55.44
  • Removed Netviewer client from install. No longer supported by Cisco.
  • Fix regression with Cimco Edit not saving .bak files.
CIMCO DNC-Max 7.55.44
  • Removed Netviewer client from install. No longer supported by Cisco.
CIMCO Software 7.55.43 PreviewReleased: 15-01-16Register to download
Changes since previous version:
CIMCO DNC-Max 7.55.43
  • Fixed error in advanced triggers where the start of line anchor could trigger immediately after a previous match.
  • Auto import: Other file prefix length has been changed to use advanced trigger. If a file matches the advanced trigger, and a file in the database matches the same trigger with same output, the file will be associated to the database file. Old installations will automatically use an advanced trigger with same behavior as before version 7.55.43.
CIMCO Software 7.55.42 PreviewReleased: 15-01-16Register to download
Changes since previous version:
CIMCO Edit 7.55.42
  • Updated Finnish translations.
  • Updated Heidenhain filter.
  • Mazak viewer updated: Can now correctly load .MTP backup files.
CIMCO CNC-Calc 7.55.42
  • Fixed issue in kernel.
CIMCO DNC-Max 7.55.42
  • Updated Finnish translations.
  • Serial Protocol: Fixed crash when using "compare report" in generic serial protocol.
  • Network Protocol: It is now possible to send associated files before main file when doing auto receive. Associated files will be left in directory until a main file is received.
CIMCO Software 7.55.41 PreviewReleased: 05-01-16Register to download
Changes since previous version:
CIMCO Edit 7.55.41
  • Fixed error in post processor.
CIMCO Software 7.55.40 PreviewReleased: 18-12-15Register to download
Changes since previous version:
CIMCO Edit 7.55.40
  • Fixed issue with Rotation.
  • Mazak viewer updated: Fixed "unknown function in network files"
  • Mazak viewer updated: Fixed T numbers in T32
CIMCO CNC-Calc 7.55.40
  • Constant Cut Milling Operation: Custom feedrate for transition lift have been added.
CIMCO Software 7.55.39 PreviewReleased: 09-12-15
Changes since previous version:
CIMCO Edit 7.55.39
  • Teamviewer client updated to version 11.
  • Fanuc filter updated: D value now supports #.
CIMCO DNC-Max 7.55.39
  • Fixed problem with delete of a template port in DB when a new port was added and Cancel button was pushed.
CIMCO MDC-Max 7.55.39
  • Fixed problem with clear condition like TIME[ISDAYSTART] on timeline -> it cleared the timer in last status on timeline.
  • Web Client: Fixed formatting of many time durations.
CIMCO NC-Base 7.55.39
  • NCBase: fixed problem with restore of programs in import queue from backup when the ncbase root directory was pointed to a different directory then the original stored in the backup.
CIMCO Software 7.55.38 PreviewReleased: 27-11-15Register to download
Changes since previous version:
CIMCO Edit 7.55.38
  • Updated German and Finish translations.
  • Fanuc filter updated: supports willemin commands.
  • Mazak viewer updated.
CIMCO DNC-Max 7.55.38
  • Updated German and Finish translations.
CIMCO Software 7.55.37 PreviewReleased: 25-11-15Register to download
Changes since previous version:
CIMCO CNC-Calc 7.55.37
  • IMPORTANT: Windows XP is no longer supported for CNC-Calc.
  • Additional test of lead in/out parameters to ensure that the correct lead in/out is used wiith compensation is in the controller.
  • Warnings are now shown when the Kernel can't make any toolpaths because or the parameters used.
  • Error with axis substitution has been corrected.
CIMCO Software 7.55.36 PreviewReleased: 18-11-15Register to download
Changes since previous version:
CIMCO Edit 7.55.36
  • Updated Chinese translations.
CIMCO DNC-Max 7.55.36
  • Updated Chinese translations.
  • Ftp server: FileZilla interface updated.
CIMCO Software 7.55.35 PreviewReleased: 13-11-15Register to download
Changes since previous version:
CIMCO CNC-Calc 7.55.35
  • The colors defined in the Global Colors setup is now used when displaying measurements and nc toolpaths in CNC-Calc.
  • New linking page inserted in Pocket, Contour and Constant cut parameters. These new parameters make it possible to optimise the operations with the following parameters: * Retract Type: Controls if every retract should be to the retract height or just to the safe distance over the part. * Use Rapid Retract: Controls if the retract should be in rapid move from the bottom or if we should move to safe distance in feed and then switch to rapid. * Plunge relative to last depth: Moving down to make a new cut should we always make the transition from rapid to feed safe distance above the part or should this transition point be relative to the last cut depth. * Staydown Distance: Works as it have always done in Contour, but now it is added to Pocket and Constant Cut as well. Staydown Distance is the maximum distance a transition move is made in the XY plane before it is replaced with a retract and reposition move.
  • Machine as selected is only in play when multiple contour pockets etc. are selected. Normally the order of the operation will be optimised but sometimes the order of operations are more important than the optimisation and in these cases "Machine as Selected" will ensure that the operations are performed in the order they were selected.
CIMCO DNC-Max 7.55.35
  • Auto import feature can now associate files to main program using sub directory structure. The main program will be the first file found in the directory. This feature is enabled when "Keep directory structure" and "Associated files in the same directory" is checked.
  • Split window: It is now possible to configure PC and CNC side allowed actions separately.
CIMCO Software 7.55.34 PreviewReleased: 04-11-15Register to download
Changes since previous version:
CIMCO Edit 7.55.34
  • Improved Fanuc Turning filter.
CIMCO DNC-Max 7.55.34
  • FTP Server: Fixed problem when using absolute path.
CIMCO Software 7.55.33 PreviewReleased: 27-10-15Register to download
Changes since previous version:
CIMCO Edit 7.55.33
  • Issue in DXF reader corrected.
  • Heidenhain filter updated: * cycles 208, 262, 267 is fixed * CYCL CALL POS added.
CIMCO CNC-Calc 7.55.33
  • Rectangle with rounded corners corrected so it now works with manual input.
CIMCO DNC-Max 7.55.33
  • Network protocol supports now subfolders for error file.
CIMCO MDC-Max 7.55.33
  • Timeline legend.
  • State duration marks in timeline.
  • Variable height of timeline.
  • Timeline export to pie charts.
  • Print support for pie charts.
  • Fixed problem with automatic events stopped after DNC server restart.
  • Added expression $COLUMNSUMHMS in machine column header for pie charts.
  • Added option to open the timeline when the MDC Client starts.
  • Added state sound notification for the Operator Screen.
CIMCO Software 7.55.32 PreviewReleased: 22-10-15Register to download
Changes since previous version:
CIMCO Edit 7.55.32
  • German translation updated.
  • Fixed "line parsing" bug
  • Changes in "IF" expressions"
CIMCO DNC-Max 7.55.32
  • German translation updated.
  • Split Window: Fixed issue with "Merge Files".
  • Added new optional backup behavior when direcotyr monitor updates nc-base. This allows the directory monitor to trigger new version number in the nc-base based on backup.
  • Fixed error in Handheld terminal Bar code dialog.
CIMCO Software 7.55.31 PreviewReleased: 14-10-15Register to download
Changes since previous version:
CIMCO Edit 7.55.31
  • Fixed an issue where Cimco Edit did not always correctly detect external file-changes.
CIMCO CNC-Calc 7.55.31
  • Fixed issue with rectangles with rounded corners.
CIMCO DNC-Max 7.55.31
  • File Operations can now delete files based on their extension. This feature is found in the File Operations sheet.
CIMCO Software 7.55.30 PreviewReleased: 13-10-15Register to download
Changes since previous version:
CIMCO Edit 7.55.30
  • Updated Korean translations.
CIMCO DNC-Max 7.55.30
  • Updated Korean translations.
  • Send File dialog: Fixed issue when not logged in as admin user.
  • Fixed problem with web clients when setting DNC-Max server network adapter to ip 0.0.0.0
  • MDC Web client: Fixed issue when using cutsom colors.
CIMCO Software 7.55.29 PreviewReleased: 06-10-15Register to download
Changes since previous version:
CIMCO Edit 7.55.29
  • Updated german translations.
  • Fixed an issue where Cimco Edit was unable to save to files, that had been opened in other editors
CIMCO CNC-Calc 7.55.29
  • German translations corrected in the face milling parameters dialog.
  • New configuration value in createFormat function. It is now possible to use the flag to specify the minimum number of decimals that should be shown in the formatted value. xyzFormat = createFormat({decimals: 3,minDecimals: 1}); will format the value 3.000 as 3.0 but the value 3.333333 will be formatted as 3.333
CIMCO DNC-Max 7.55.29
  • Network Protocol: FTP Synchronization now also works when the "local" path is a UNC path and will not report connection errors from the passive synchronization when the remote server is not online.
CIMCO Software 7.55.28 PreviewReleased: 29-09-15Register to download
Changes since previous version:
CIMCO DNC-Max 7.55.28
  • DNC-Max ignores FTP sending when sending Remote Requested file and "Send File" or "Synchronize FTP Directory with $INCOMING" is enabled.
  • Rename from main network sheet no longer applies if Send File is disabled.
  • Fixed configuration dialog for ioLogik device.
CIMCO Software 7.55.27 PreviewReleased: 21-09-15Register to download
Changes since previous version:
CIMCO Edit 7.55.27
  • Heidenhain new is chosen as default in backplot when using Heidenhain files.
CIMCO DNC-Max 7.55.27
  • Standard Serial Protocol: Fixed issue with receiving files larger than 16KB.
CIMCO MDC-Max 7.55.27
  • Improved MDC-Max web client performance.
CIMCO Software 7.55.26 PreviewReleased: 16-09-15Register to download
Changes since previous version:
CIMCO Edit 7.55.26
  • Fixed G96/G97 issue for Fanuc.
CIMCO DNC-Max 7.55.26
  • Standard Serial Protocol: Fixed not being able to resend local file.
CIMCO MDC-Max 7.55.26
  • Fixed memory issue for MDC-Max.
CIMCO Software 7.55.25 PreviewReleased: 11-09-15Register to download
Changes since previous version:
CIMCO CNC-Calc 7.55.25
  • Fixed error where changed Custom Feedrates would not be saved.
CIMCO MDC-Max 7.55.25
  • extended MDC automatic events/alerts with 8 fields which can realtime evaluate MDC expressions.
  • MDC alerts/events can be exported to OEMLink.
  • Added reading work zero offset (G54-G59) from Fanuc controllers in Focas protocol.
CIMCO NC-Base 7.55.25
  • Fixed issue with the "Edit file notes" functionality in NC-Base.
CIMCO Software 7.55.24 PreviewReleased: 03-09-15Register to download
Changes since previous version:
CIMCO DNC-Max 7.55.24
  • Fixed problem with auto receive execute would not pass static arguments to command line.
  • Split-window: Fixed error where CNC-side sorting would forget chosen sort method.
CIMCO MDC-Max 7.55.24
  • Added reading overrides (feed, rapid, spindle) in Focas protocol.
  • Added reading PMC variables from Fanuc controller in Focas protocol.
  • NETLink protocol optimization.
CIMCO NC-Base 7.55.24
  • Fixed error when previewing .rtf file would cause preview window to be stuck on the .rtf file.
CIMCO Software 7.55.23 PreviewReleased: 28-08-15Register to download
Changes since previous version:
CIMCO DNC-Max 7.55.23
  • Creating folder on CNC using LSV2 has been improved.
CIMCO NC-Base 7.55.23
  • Fixed error with program format duplicating last 2 characters in line.
CIMCO Software 7.55.22 PreviewReleased: 17-08-15Register to download
Changes since previous version:
CIMCO DNC-Max 7.55.22
  • Fixed problem with Auto Receive execute not passing all arguments to command-line.
  • Auto Receive/Remote Request Execute can now pass file without path as argument to command-line. A new checkbox has been added to execute configuration.
CIMCO MDC-Max 7.55.22
  • Fixed problem when saving timer group configuration.
CIMCO NC-Base 7.55.22
  • Fixed error where purging file from NC-Base would leave file on hard drive.
  • Fixed problem with program format missing new lines.
CIMCO Software 7.55.21 PreviewReleased: 10-08-15Register to download
Changes since previous version:
CIMCO Edit 7.55.21
  • Fixed problem with export to DXF missing small arcs.
CIMCO DNC-Max 7.55.21
  • Split-window can now sort files and directories on the CNC side.
CIMCO Software 7.55.20 PreviewReleased: 05-08-15Register to download
Changes since previous version:
CIMCO Edit 7.55.20
  • Updated Mazatrol viewer.
CIMCO DNC-Max 7.55.20
  • New serial port for Woyda machines.
  • DNC-MaxCtrl can now send entire folders to a CNC. To send the contents of a folder use the argument -"sf". The file argument in the command line must end in a slash to trigger folder send. Use the argument "-kf" to create the a folder with the same name on the CNC and send the files to that folder.
CIMCO MDC-Max 7.55.20
  • Fixed reload of live configuration when engine configuration is changed.
CIMCO NC-Base 7.55.20
  • Fixed crash when switching previews in editor with some file formats.
CIMCO Software 7.55.19 PreviewReleased: 03-08-15Register to download
Changes since previous version:
CIMCO Edit 7.55.19
  • Updated Mazatrol viewer.
CIMCO DNC-Max 7.55.19
  • Fixed translation in IO logic configuration sheet.
CIMCO MDC-Max 7.55.19
  • Fixed reload live configuration when engine configuration is changed.
  • Added support for reading Feed/Rapid/Spindle overrides from fanuc controllers via focas.
  • Added restart netlink adapter when gets ready.
  • Fixed pie charts in html report.
  • Fixed DB integrity check dialog.
CIMCO Software 7.55.18 PreviewReleased: 28-07-15Register to download
Changes since previous version:
CIMCO CNC-Calc 7.55.18
  • Problem with compensation off fixed.
CIMCO Software 7.55.17 PreviewReleased: 20-07-15Register to download
Changes since previous version:
CIMCO CNC-Calc 7.55.17
  • Axis Substitution is now supported, In order for this to work you have to use the new post processors, and some configuration are also needed. In the CNC-Calc setup dialog the name of the rotating axis and the tolerance has to be defined and then it can be enabled and the diameter set in the lower left corner of the CNC-Calc screen.
CIMCO Software 7.55.16 PreviewReleased: 17-07-15Register to download
Changes since previous version:
CIMCO NC-Base 7.55.16
  • It is now possible when accepting a program on the import queue to "Accept to multiple machines". This will accept the queued file as usual and immediately copy it to overwrite other programs with identical names in other machines of the user's choice. This option is useful if one program file is used on several similar machines.
CIMCO Software 7.55.15 PreviewReleased: 03-07-15
Changes since previous version:
CIMCO Edit 7.55.15
  • There is now a progress dialog for all the longer lasting operations. This is useful for Constant Cut Milling.
  • The CNC tool path rapid moves are not shown as yellow. This makes it possible to distinguish them from cutting moves
CIMCO Software 7.55.14 PreviewReleased: 02-07-15
Changes since previous version:
CIMCO Edit 7.55.14
  • Updated German translation.
CIMCO DNC-Max 7.55.14
  • Updated German translation.
CIMCO Software 7.55.13 PreviewReleased: 26-06-15Register to download
Changes since previous version:
CIMCO Edit 7.55.13
  • Mazak ISO control: Fixed bug with tool definition.
  • Fanuc/ISO control: Fixed and improved G16, now it supports G90/91, using last position as a pivot point and selection of G17/G18/G19.
  • Updated German translation.
CIMCO DNC-Max 7.55.13
  • Updated German translation.
CIMCO NC-Base 7.55.13
  • Fixed problem in Server Settings: "Disable customer info" and "Disable project", projects can now enabled without having customers.
CIMCO Software 7.55.12 PreviewReleased: 24-06-15Register to download
Changes since previous version:
CIMCO Edit 7.55.12
  • Updated German translation.
CIMCO DNC-Max 7.55.12
  • Serial protocol: Fixed not being able to disable send translator when using "Send File Advanced".
  • Fixed issue with sending many large local files to DNC-Max server.
CIMCO Software 7.55.11 PreviewReleased: 22-06-15Register to download
Changes since previous version:
CIMCO CNC-Calc 7.55.11
  • Now all Mill Post Processors have the Long Hand drilling implemented. The following drilling types are supported: "Drilling", "Standard Peck Drilling", "Rapid Peck Drilling" and "Reaming".
CIMCO Software 7.55.10 PreviewReleased: 17-06-15Register to download
Changes since previous version:
CIMCO Edit 7.55.10
  • Added Okuma samples.
CIMCO CNC-Calc 7.55.10
  • Added Constant Cut Operation. This is a very powerful operation to mill open pocket and surfaces with protrusions etc.
CIMCO DNC-Max 7.55.10
  • Fixed issue with split window when split window opened in a network path.
  • Fixed issue with split window not refreshing CNC directory after some operations.
  • FTP Server: Added new Mazak FTP Server behavior. This has Mazak compatibility enabled as default, and has some special command handling that should make it easier for Mazak users. Mazak compatibility is still available for other FTP Server behaviours.
  • FTP Server: Fixed issue with FTP REST command.
  • FTP Server: Fixed issue with remembering last entered path.
CIMCO Software 7.55.09 PreviewReleased: 09-06-15Register to download
Changes since previous version:
CIMCO Edit 7.55.09
  • Updated Okuma control: Added IF, GOTO, EQ, LT, GT, NE.
  • Updated APT control: Fixed issue with empty backplot.
  • Updated Fanuc/ISO control: * Subroutine call Haas-style using M98, M98 Q L for repetitions and slightly rotated drill pattern. * Incremental H value for C-axis H is now used properly case of G43 command.
  • Fixed problem with MiniDNC's config location because MiniDNC uses the editors config directory.
  • Updated German translation.
CIMCO DNC-Max 7.55.09
  • Updated German translation.
CIMCO Software 7.55.08 PreviewReleased: 04-06-15Register to download
Changes since previous version:
CIMCO Edit 7.55.08
  • Updated Mazatrol viewer.
  • Updated Fanuc/ISO: Fixed retract in G53.
CIMCO DNC-Max 7.55.08
  • Mazak protocol: Changed maximum comment length for MAZAK MPLUS and TPLUS to 32, and M64 to 48
  • Auto receive: When "Update fields after receiving" and the setting in NC-Base "Update program fields from associated files" is checked, associated files will be scanned.
  • Auto import: When "Use folder name as program name" and the setting in NC-Base "Update program fields from associated files" is checked, associated files will be scanned.
CIMCO NC-Base 7.55.08
  • Added option "Update program fields from associated files", used by Program Format to enable scanning of associated files.
CIMCO Software 7.55.07 PreviewReleased: 02-06-15Register to download
Changes since previous version:
CIMCO DNC-Max 7.55.07
  • FTP Server (FileZilla, and Default): Fixed issue with NLST command and CWD *
CIMCO Software 7.55.06 PreviewReleased: 28-05-15Register to download
Changes since previous version:
CIMCO Edit 7.55.06
  • Fanuc/ISO control: G53 is now handled as G28.
CIMCO Software 7.55.05 PreviewReleased: 26-05-15Register to download
Changes since previous version:
CIMCO Edit 7.55.05
  • Updated Mazatrol viewer.
CIMCO CNC-Calc 7.55.05
  • Updated Heidenhain Post Processors: There was an error in the calculation of relative and absolute depths in the drill cycles. All parameter lines in the cycle lines are now terminated with a Tilde char.
CIMCO DNC-Max 7.55.05
  • Updated Network Protocol: Split Window now also shows the directory when presenting error for files that cannot be transferred.
CIMCO Software 7.55.04 PreviewReleased: 20-05-15Register to download
Changes since previous version:
CIMCO Edit 7.55.04
  • Updated Mazatrol viewer.
CIMCO Software 7.55.03 PreviewReleased: 18-05-15Register to download
Changes since previous version:
CIMCO Edit 7.55.03
  • Updated Portuguese translation.
CIMCO DNC-Max 7.55.03
  • Fixed issue where default files extension for the send/receive window was filled with garbled text.
  • Updated Portuguese translation.
CIMCO Software 7.55.02 PreviewReleased: 15-05-15Register to download
Changes since previous version:
CIMCO Edit 7.55.02
  • External Commands: Added option: "Wait for output from program": * Enabled external commands works as usual. * Disabled the editor will not wait for the external command to finish, and not open $OUTFILE.
CIMCO NC-Base 7.55.02
  • Added two command line arguments: /ncbaseminimal - Opens NC-Base in minimal mode. /ncbasesuperminimal - Opens NC-Base in super minimal mode.
CIMCO Software 7.55.01 PreviewReleased: 08-05-15Register to download
Changes since previous version:
CIMCO Edit 7.55.01
  • Added new feature: The user can now be warned about files being open in multiple instances of the Editor at the same time. This option is available in the Editor setup window under General Tab.
CIMCO CNC-Calc 7.55.01
  • Updated kernel.
CIMCO DNC-Max 7.55.01
  • FTP Server: Fixed problems with current client directory changing for all connected clients.
  • Updated Network Protocol: The configuration sheet Advanced->Other has been replaced by two new sheets, Advanced->Protocol and Advanced->Split Window.
  • Updated Network Protocol: The "delete" button in the split window can now be disabled by unchecking "Allow deletion of files and folders" in Advanced->Split Window
  • Updated Network Protocol: A set of default file extensions can be set for the split window under Advanced->Split Window.
CIMCO MDC-Max 7.55.01
  • Fixed issue where MDC-Max would crash if color selection in Graph Report Setup was attempted and Live Setup had not been opened.
CIMCO Software 7.55.00 PreviewReleased: 05-05-15Register to download
Changes since previous version:
CIMCO Edit 7.55.00
  • Updated Portuguese translation.
CIMCO DNC-Max 7.55.00
  • Updated Network Protocol: Split window now informs user if files cannot be sent, deleted or renamed.
  • New telnet command "REQUESTFILE" - call remote request on dnc port.
  • New parameter in DNCMaxCtrl app: -r = Remote request.
  • Updated Portuguese translation.
CIMCO MDC-Max 7.55.00
  • Split MDC configuration allowing changes in reports and live/operator screens without recalculation.
  • Export of time line to XML.
CIMCO NC-Base 7.55.00
  • Permission: "Import queue programs read-only" now applies to both the program on the import queue and the current program.
CIMCO Software 7.50.23 PreviewReleased: 30-04-15Register to download
Changes since previous version:
CIMCO Edit 7.50.23
  • Fanuc/ISO control: G990 fixed, XYZ and UVW coordinates can now be used together.
CIMCO Software 7.50.22 PreviewReleased: 29-04-15Register to download
Changes since previous version:
CIMCO Edit 7.50.22
  • Siemens control: Added support for the "Ignore M6" setting.
CIMCO Software 7.50.21 PreviewReleased: 24-04-15Register to download
Changes since previous version:
CIMCO CNC-Calc 7.50.21
  • Radial turning is now implemented. That means that all roughing operations now can be made as Axial (as it was) or Radial. This option is set on the first configuration page of the roughing parameters.
CIMCO DNC-Max 7.50.21
  • FTP Server: It is now possible to set a timeout period for FTP clients connecting to DNC-Max FTP Server.
CIMCO MDC-Max 7.50.21
  • Web Client: Improved setup excel tab: Disable check box when report is not type of time line.
  • Web Client: Added a new option for time line export: Sum states on time line.
CIMCO NC-Base 7.50.21
  • Added "Notify on programs with import conflict" and read-only permission check to the button: "View imported file". Only showing file name not full path of imported file with conflict.
  • Added "Awaiting approval" to imported files when double clicking on them.
CIMCO Software 7.50.20 PreviewReleased: 21-04-15Register to download
Changes since previous version:
CIMCO Edit 7.50.20
  • Added new Okuma control type: Okuma Milling (Beta), Okuma Turning (Beta).
  • Added new Mazak ISO control type: Mazak ISO Milling (New), Mazak ISO Turning (New).
  • When inserting macros, moved check for valid input to when the user presses OK.
  • Updated Mazatrol viewer.
CIMCO CNC-Calc 7.50.20
  • Invalid Helix and Ramp movements corrected.
  • Error with very small circles in contour is corrected.
CIMCO DNC-Max 7.50.20
  • Directory Monitor: Fixed problem with setting seconds for directory scan interval.
  • FTP Server: Fixed problem with sockets sometimes not being closed correctly by FTP Server.
  • Updated Network Protocol: Split window can now list directories using LSV2 for TNC640 machines. Empty files (files with size 0) will be regarded as directories for TNC640 machines.
CIMCO Software 7.50.19 PreviewReleased: 17-04-15Register to download
Changes since previous version:
CIMCO Edit 7.50.19
  • Updated Heidenhain New control: Added cycle 241.
CIMCO CNC-Calc 7.50.19
  • Wrong ramp entries have been corrected.
CIMCO DNC-Max 7.50.19
  • Minor fixes to UNC Directory Login configuration interface.
  • Network protocol: Fixed error where configuration of ignored directories for auto receive set was lost.
CIMCO NC-Base 7.50.19
  • Added permission: "Import queue programs read-only".
  • Added option: "Notify on programs with import conflict" this notifies the user and changes the background color of the editor window when they open a import file or a file with a import waiting approval.
CIMCO Software 7.50.18 PreviewReleased: 16-04-15Register to download
Changes since previous version:
CIMCO Edit 7.50.18
  • APT Control: Supported different variation of MOVARC syntax.
  • Fanuc/ISO control: Added support for G990 command.
  • Fixed problem with configuring CNC-Calc when using floating licences.
CIMCO DNC-Max 7.50.18
  • The setting "Do not place received files on the import queue" in Directory Monitor and Generic Serial ports' Auto Receive set specific NC-Base settings has been reworked to make files handled by the autoreceive set behave exactly as if the setting "Place files on the import queue" in the port NCBase settings was not enabled.
  • Updated network protocol: Receiving files in split window can now chosen to be placed in the directory shown in the split window when NC-Base export is enabled.
CIMCO MDC-Max 7.50.18
  • Web Client: Mitigate issue when ghost live screens exist.
CIMCO Software 7.50.17 PreviewReleased: 13-04-15Register to download
Changes since previous version:
CIMCO Edit 7.50.17
  • Updated Heidenhain Macros: Cycle 200 and 203 (added parameter Q395)
CIMCO DNC-Max 7.50.17
  • Updated Network Protocol: Send File advanced can now send and receive folders using FTP and LSV2 protocol. Can receive folders using FOCAS protocol, and can send folders on FOCAS machines that allows directory creation.
  • Updated Network Protocol: Send File advanced can now rename file and folders on pc side and on cnc side using FTP protocol. Using LSV2 protocol, files can be renamed on cnc side.
  • Updated Auto Import feature: Auto import can now import folders put into the import directory, and use the folder name as the program name in NC-Base.
  • Updated sending from NC-Base: When sending from the NC-Base, it is now possible to send entire folders using the FTP,LSV2 or FOCAS protocols. If the files in the NC-Base is located in a folder, they will be send to a folder with the same name on the cnc.
CIMCO MDC-Max 7.50.17
  • Disable calculation on Excel side when the table is exported to Excel, this makes export to the Excel faster.
CIMCO Software 7.50.16 PreviewReleased: 10-04-15Register to download
Changes since previous version:
CIMCO Edit 7.50.16
  • Updated French translation.
CIMCO CNC-Calc 7.50.16
  • Changed default post-processor for ISO Mill to: fanuc NO K
CIMCO DNC-Max 7.50.16
  • Updated French translation.
  • DNC-Max Client Plugin for Editor now knows if it is licensed using the License Server.
  • FTP Synchronization: Files transferred from ftp to local machine are now added to FTPSync's cache of local files.
CIMCO MDC-Max 7.50.16
  • Only RTS output in the HHT port can be specified like output.
CIMCO Software 7.50.15 PreviewReleased: 09-04-15Register to download
Changes since previous version:
CIMCO CNC-Calc 7.50.15
  • Updated kernel.
CIMCO Software 7.50.14 PreviewReleased: 07-04-15Register to download
Changes since previous version:
CIMCO Edit 7.50.14
  • Updated Solid Animation
CIMCO Software 7.50.13 PreviewReleased: 01-04-15Register to download
Changes since previous version:
CIMCO Edit 7.50.13
  • Updated Roeders control: Improved support for IF operator with system variables. IF statement operator, containing user defined variables in the condition, is being always evaluated now as TRUE.
CIMCO CNC-Calc 7.50.13
  • Updated kernel.
CIMCO MDC-Max 7.50.13
  • Timer group settings will once again apply to all timers.
  • The User defined colors in the Color picker will now persist between MDC-Max launches.
CIMCO Software 7.50.12 PreviewReleased: 31-03-15Register to download
Changes since previous version:
CIMCO MDC-Max 7.50.12
  • Timeline can be exported to excel as raw data.
  • Recalculation start can be set to any hour of the previous day (Recalculation is alwaystime for last 24 hours)
  • Events of type DB can write values to MSGVAR1 - MSGVAR8 (Supported $JOB, $PROGRAM, $OPERATOR, ...)
CIMCO Software 7.50.11 PreviewReleased: 30-03-15
Changes since previous version:
CIMCO DNC-Max 7.50.11
  • Fixed problem with checkboxes in UNC Directories interface not loading properly from machine file.
CIMCO Software 7.50.10 PreviewReleased: 27-03-15Register to download
Changes since previous version:
CIMCO Edit 7.50.10
  • Fanuc/ISO control: * G73/G83 peck drilling fix. * G73 turning cycle fix. * Cumulative fix for all cycles (milling and turning) that use R value as integer parameter.
  • Updated German translation.
  • Optimized space usage for macros with much text and many fields.
CIMCO CNC-Calc 7.50.10
  • Safe Distance is added to the Facing Operation.
  • All Milling operations now have custom feedrates implemented.
  • Milling kernel has been corrected for an error in contour, the direction of the contour was wrong.
  • Text and True Type Text Milling dialogs have been corrected.
  • The internal milling of True type Text is now done with pocket milling. So now all the options in pocket milling are available for this type of operation.
CIMCO Software 7.50.09 PreviewReleased: 25-03-15Register to download
Changes since previous version:
CIMCO Edit 7.50.09
  • Fixed issue with searching for strings with Latin characters.
  • Fixed issue with Replace not working correctly with search strings containing Latin characters.
  • Fixed issue with converting to Lowercase/Uppercase not working correctly with files containing Latin characters.
  • Fixed an issue where 'line numbers' are drawn even though they have been disabled.
CIMCO DNC-Max 7.50.09
  • Updated network protocol: When sending file, using LSV2, FOCAS or FTP machine protocol with NC-Base link enabled, the file can be renamed using a database field chosen by the user.
CIMCO NC-Base 7.50.09
  • Added option to make fields required for sending to a DNC-Max port.
CIMCO Software 7.50.08 PreviewReleased: 18-03-15Register to download
Changes since previous version:
CIMCO Edit 7.50.08
  • Updated Heidenhain New control: Fixed M128/129 command.
CIMCO CNC-Calc 7.50.08
  • Normal text entry is corrected so that a capital L is now the entered text height.
CIMCO Software 7.50.07 PreviewReleased: 17-03-15Register to download
Changes since previous version:
CIMCO Edit 7.50.07
  • Fanuc/ISO control: Fixed loop execution in FANUC Macro B.
  • Fixed problem with min/max values for tool Toolpath Statistics milling.
  • Added NCI filter: NCI is now supported in both Backplot and Solid Animation.
CIMCO DNC-Max 7.50.07
  • Updated Network protocol: Send file advanced for ftp client protocol can now create a new folder on the CNC/FTP server.
CIMCO MDC-Max 7.50.07
  • Added new configuration sheet, "State/indicator presets" which can be used to predefine settings for the sheets: * "Status Screens: States" * "Status Screens: Lights / Indicators" * "Operator Screens: Show State" Any number of predefinitions can be set and then chosen in any of the above mentioned sheets. Settings previously set in any of the sheets "Status Screens: States", "Status Screens: Lights / Indicators" and "Operator Screens: Show State" can easily be defined as a predefined settings set to be used elsewhere. If a set already exists which is identical to what is being exported, the user is asked whether to use that set instead of adding a new duplicate version.
CIMCO Software 7.50.06 PreviewReleased: 16-03-15Register to download
Changes since previous version:
CIMCO Edit 7.50.06
  • Transmission: Fixed Machine setup - Transmission dialog.
CIMCO Software 7.50.05 PreviewReleased: 13-03-15Register to download
Changes since previous version:
CIMCO CNC-Calc 7.50.05
  • Updated kernel.
  • TrueType outline now working.
CIMCO DNC-Max 7.50.05
  • Updated Network protocol: Send file advanced for LSV2 machine protocol can now create a new folder on the CNC.
  • Updated Serial protocol: Can now automatically restart DNC port after transmit operation or after completed remote request.
CIMCO MDC-Max 7.50.05
  • Added support for storing of Excel Templates in database.
  • Added option for switch Row/Column.
CIMCO Software 7.50.04 PreviewReleased: 12-03-15
Changes since previous version:
CIMCO Edit 7.50.04
  • Roeders Milling: Enabled XCALL for all possible file names.
  • Heidenhain file type: Added 8 macros, Cycle 208, 209, 251, 252, 256, 257, 262, 267
  • CNC-Calc can now open 10 windows.
CIMCO Software 7.50.03 PreviewReleased: 11-03-15Register to download
Changes since previous version:
CIMCO Edit 7.50.03
  • Updated French and Danish translation.
CIMCO DNC-Max 7.50.03
  • Updated French and Danish translation.
  • Fixed problem with auto receive in Serial port.
CIMCO MDC-Max 7.50.03
  • Updated MDC client: original “System setup" was splitted up into "Client options" and "System setup" Avoid recalculation when Client settings were changed.
  • Updated MDC client: Fixed problem with start time in Backdating window.
  • Updated MDC client: System setup moved to a window tab.
  • Updated MDC client: Fixed problem with log off.
  • Fixed problem with "Calculating..." when traditional engine is used.
  • Excel is disabled when Backdating engine is used.
  • Web Client: Add compatibility with new operator screen button features.
  • Web Client: Fix improper display of TIME, DATE and DATETIME fields.
CIMCO Software 7.50.02 PreviewReleased: 10-03-15
Changes since previous version:
CIMCO Edit 7.50.02
  • Updated Polish translation.
CIMCO DNC-Max 7.50.02
  • Updated Polish translation.
  • Updated Directory Monitor: Auto receive set can now ignore directories set in AutoRecv/RemReq configuration window. The ignored directories is chosen in the auto receive set ignore directory window.
  • Updated Directory Monitor/Standart Serial: Auto receive can now execute an external program after receiving a file. Parameters to the external program can be specified either in the file itself or by writing a command line string in the auto receive execute configuration window.
  • Updated LSV-2 TCP/IP network protocol: It can now send and receive directories to and from a heidenhain cnc using the split window (send file advanced).
  • When placing a file received using auto receive on the nc base import queue, the file will no longer be deleted before being put on the queue.
  • If the "Delete auto received files from the monitoring directory" is unchecked, the NC Base will no longer delete the file when it is placed on the import queue.
CIMCO Software 7.50.01 PreviewReleased: 06-03-15Register to download
Changes since previous version:
CIMCO CNC-Calc 7.50.01
  • The kernel for generation of toolpaths have been changed for both milling and turning. For now they should work with the feature set of the original kernels but that will be extended soon.
CIMCO Software 7.20.10 PreviewReleased: 05-03-15Register to download
Changes since previous version:
CIMCO DNC-Max 7.20.10
  • Updated Fanuc FOCAS: Added feature for creating and deleting folders.
  • Updated Fanuc FOCAS: Access to CNC_MEM and DATA_SRV.
CIMCO MDC-Max 7.20.10
  • Fixed evaluating of Excel export name.
  • Fixed scroll in backdating window when upload was pushed.
  • Added feature for searching backdated messages based on schedule.
  • Fixed multiple chart table - showed only one column.
  • Added log when a new MDC configuration is stored in DB.
CIMCO Software 7.20.09 PreviewReleased: 19-02-15Register to download
Changes since previous version:
CIMCO Edit 7.20.09
  • Updated Bookmarks: * Double-clicking a bookmark in View Bookmarks dialog will now quickly jump to the bookmark. * If line numbers have been disabled in the Editor, they will be temporarily displayed when toggling Bookmarks Indicators. * Better handling of Bookmark "Go To": if a File has been deleted, the user can choose to delete all bookmarks associated with that file. * Show Keyboard shortcuts for Bookmarks in the Contextual Menu. * View Bookmarks button is always enabled, even when no files are open.
  • Fanuc/ISO Control: Tool offset values a being read an substitute now in turn modes.
  • Updated Finnish translation.
CIMCO DNC-Max 7.20.09
  • Updated FTP Server: Expanded FileZilla engine response behavior.
  • Updated Finnish translation.
CIMCO MDC-Max 7.20.09
  • Added a new MDC server engine supporting backdating and single MDC port recalculation.
CIMCO Software 7.20.08 PreviewReleased: 17-02-15Register to download
Changes since previous version:
CIMCO Edit 7.20.08
  • Updated Mazatrol viewer.
  • Setup CNC-Calc: Added link to Post Processor Manual.
CIMCO DNC-Max 7.20.08
  • UNC Login errors now give a description.
  • Updated DNC-Max and MDC-Max Web clients: IP address and port settings are now read from DNC-Max server configuration. The web clients will now work if the IP address is changed under "server configuration" -> "network setting" -> "use network adapter".
  • Updated FTP Server port: It is now possible to adjust the FTP Server engine 3 types of engines are available: * "Default" Behaves as the normal DNC-Max FTP Server. * "FileZilla" Emulates FileZilla server. * "Lenient" Will reply with a success if the outcome of a request is the same even if it has failed (for example creating a directory that already exists).
CIMCO Software 7.20.07 PreviewReleased: 11-02-15Register to download
Changes since previous version:
CIMCO Edit 7.20.07
  • Fanuc/ISO control: Fixed G74, G75, G83, G84, G85, G484 and G984.
CIMCO MDC-Max 7.20.07
  • The first timer in the Timer List will no longer reset Event to default when the System Configuration Window is opened.
  • Fixed write configuration for order view when order view was not activated.
CIMCO NC-Base 7.20.07
  • Fixed problem where the Mazak preview window in NC-Base client some times becomes blank.
CIMCO Software 7.20.06 PreviewReleased: 06-02-15Register to download
Changes since previous version:
CIMCO Edit 7.20.06
  • Fanuc/ISO control: Fixed G71 and added support for G72 facing stock removal.
  • Fanuc/ISO and Siemens 840D: Fix. Non-breaking space is now treated as ordinary space character.
  • Updated Korean translation.
CIMCO DNC-Max 7.20.06
  • Updated Korean translation.
CIMCO MDC-Max 7.20.06
  • Invalid timer settings should no longer cause issues with migration of config format for timer settings pre-7.20.05 to post-7.20.05.
CIMCO Software 7.20.05 PreviewReleased: 05-02-15Register to download
Changes since previous version:
CIMCO MDC-Max 7.20.05
  • Fixed backward compatibility for the MDC configuration.
  • Added new feature: Timer Groups. Grouping timers together will allow you to set the timers within a group to be mutually exclusive. Making timers mutually exclusive will add to the end of each timer's stop conditions the start conditions of every other timer in the group. It is also possible to set stop conditions that apply to every timer in the group. This new feature is available as a sub-item to Timers in the MDC-Max System Setup. The option of setting a custom color for items in Live Screens and Operator Screens which were previously limited to specific colors has been added.
CIMCO Software 7.20.04 PreviewReleased: 03-02-15Register to download
Changes since previous version:
CIMCO Edit 7.20.04
  • Fixed problem with Replace All.
  • Fanuc/ISO control: Fixed rare bug preventing tool animation in backplot.
  • Added Mazak ISO Turning (New).
CIMCO Software 7.20.03 PreviewReleased: 30-01-15Register to download
Changes since previous version:
CIMCO Edit 7.20.03
  • Fixed problem with Backplot background turning green.
CIMCO MDC-Max 7.20.03
  • MT-Connect added ESTOPON/ESTOPOFF messages.
  • Restart MT-Connect agent from the DNC Admin.
  • Added custom SQL query for the Order View.
CIMCO Software 7.20.02 PreviewReleased: 29-01-15Register to download
Changes since previous version:
CIMCO Edit 7.20.02
  • Added Bookmarks functionality to Editor. Bookmarks can be added, named, and removed. User can view all Bookmarks for all files, and navigate quickly to each bookmark.
  • Updated multi channel view: It now ignores Comments and Block-skip.
  • Updated Millplus control: Fixed crash caused by NC code containing incorrect usage of G22 command.
CIMCO MDC-Max 7.20.02
  • Added backdating features.
CIMCO Software 7.20.01 PreviewReleased: 26-01-15Register to download
Changes since previous version:
CIMCO Edit 7.20.01
  • Search in files with regular expressions (Perl) are now supported.
  • Fanuc/ISO control: Possible misbehave of G66 is fixed.
CIMCO MDC-Max 7.20.01
  • New skin.
CIMCO Software 7.01.28 PreviewReleased: 21-01-15Register to download
Changes since previous version:
CIMCO DNC-Max 7.01.28
  • Added UNC login support to DNC-Max ports. This feature is available as a sub-item to Directories under port configuration.
  • Fixed error in ftp server when trying to delete file from ftp client.
CIMCO Software 7.01.27 PreviewReleased: 20-01-15Register to download
Changes since previous version:
CIMCO Edit 7.01.27
  • Updated Siemens 840D Control.
CIMCO Software 7.01.26 PreviewReleased: 19-01-15Register to download
Changes since previous version:
CIMCO Edit 7.01.26
  • Updated Solid Animation (New OpenGL)
CIMCO DNC-Max 7.01.26
  • Fixed problem with receiving MDC bar-codes when serial port does not have Autoreceive active.
  • Decreased wait time before force shut down of the DNC server.
  • Un-terminated threads are listed then in sys/system.log.
  • Added feature for wild char remote request for hand held terminal.
CIMCO Software 7.01.25 PreviewReleased: 14-01-15Register to download
Changes since previous version:
CIMCO Edit 7.01.25
  • Updated Mazatrol viewer.
  • Updated Solid Animation: Fix of interpolation bug.
  • Updated French and Danish translation.
CIMCO DNC-Max 7.01.25
  • Updated French and Danish translation.
CIMCO Software 7.01.24 PreviewReleased: 13-01-15Register to download
Changes since previous version:
CIMCO Edit 7.01.24
  • Fixed an issue where Mazatrol Viewer and CNC-Calc could fail to be licensed when using a local key file.
  • Optimized monitoring of files for external changes.
CIMCO MDC-Max 7.01.24
  • MDC Client improve close tabs.
CIMCO Software 7.01.23 PreviewReleased: 08-01-15Register to download
Changes since previous version:
CIMCO Edit 7.01.23
  • Fixed problem with CNC-Calc post processor missing the first time the editor is started.
  • Backplot/Solid Animation: Changed the way the editor saves the Control Type, now the Control Type can only be changed permanently using Bacplot setup, any change of filter while simulating will not be saved.
  • Updated Solid Animation.
  • Siemens Control: Fixed CYCLE95, please note labels MUST be unique in the NC program.
  • Updated Korean and German translation.
CIMCO DNC-Max 7.01.23
  • Updated FTP server * Fixed issue with some FTP clients using relative path in CWD command * NLST command returns now list of files + folders (before only files).
  • Updated Korean and German translation.
CIMCO MDC-Max 7.01.23
  • Added new feature Order-view that allows searching for job/orders.
CIMCO Software 7.01.22 PreviewReleased: 18-12-14Register to download
Changes since previous version:
CIMCO Edit 7.01.22
  • Backplot/Solid animation automatic tool scan: * Fixed problem with matching tool types, * Fixed problem with matching tool names that contain spaces.
CIMCO DNC-Max 7.01.22
  • Directory Monitor: Added option to merge sub-programs into main program when auto-receiving programs with associated sub-programs.
CIMCO Software 7.01.21 PreviewReleased: 10-12-14Register to download
Changes since previous version:
CIMCO Edit 7.01.21
  • Updated Heidenhain New: Added cycles 256/257
  • Fixed minimize when NC-Base is not enabled.
  • Floating Mazatrol viewer and CNC-Calc licenses will now be released when they are not used, this removes the need to restart the editor.
CIMCO Software 7.01.20 PreviewReleased: 05-12-14Register to download
Changes since previous version:
CIMCO Edit 7.01.20
  • Updated Fanuc/ISO control: * Support of Star G266 command. * Corrected retract direction in G71 cycle for sub-spindles.
  • Backplot/Solid animation: Added new control "ISO Milling (Old AGIEs)"
  • Updated French translation.
  • Updated Mazatrol viewer.
CIMCO DNC-Max 7.01.20
  • Directory Monitor - Send file: Added new option "Clean directory before scanning", this deletes files in the directory older than the interval defined in "Delete files after".
  • Updated French translation.
CIMCO MDC-Max 7.01.20
  • Fixed problem with loosing MDC configuration when there is a problem with network connection.
CIMCO NC-Base 7.01.20
  • Added option to "Save local" when saving programs in the editor with NC-Base.
  • Fixed problem with merging of 2 databases when there is more then 10000 programs.
CIMCO Software 7.01.19 PreviewReleased: 26-11-14Register to download
Changes since previous version:
CIMCO Edit 7.01.19
  • Solid animation: Fixed problem with location of cylindrical stock.
  • Backplot/Solid animation: Fixed problem in Solid Setup with displaying correct dialog when using cylindrical stock.
  • Updated Mazatrol viewer.
CIMCO DNC-Max 7.01.19
  • 'Send all NCBase programs matching the request' now also works for Hand held Terminal requests in Directory Monitor protocol.
CIMCO Software 7.01.18 PreviewReleased: 24-11-14Register to download
Changes since previous version:
CIMCO Edit 7.01.18
  • Updated Heidenhain New: Fixed bugs with external files and labels.
CIMCO MDC-Max 7.01.18
  • Fixed problem with showing bubble on time line when the resolution is lower than 32bit.
  • Fixed MDC Outputs in hand held terminal.
CIMCO Software 7.01.17 PreviewReleased: 17-11-14Register to download
Changes since previous version:
CIMCO Edit 7.01.17
  • Re-Enable decimals in CNC-Calc configuration.
  • Updated Mazatrol viewer.
  • Updated Chinese translation.
CIMCO DNC-Max 7.01.17
  • Updated Chinese translation.
CIMCO MDC-Max 7.01.17
  • Small fixes in MDC client event log.
  • Event log close improvements.
CIMCO Software 7.01.16 PreviewReleased: 12-11-14Register to download
Changes since previous version:
CIMCO Edit 7.01.16
  • New tool list generator: * Fixed crash when choosing comment lines. * Enabled support for # as a value for variables. * Extract from file: STOP_AFTER_LINES now only returns 1 line when set to 1. * Extract from file: Removed newline for on last line returned.
  • Updated CNC-Calc.
  • Updated Chinese translation.
CIMCO DNC-Max 7.01.16
  • Directory Monitor: Added option to send all NC-Base entries that match when using Remote Requests with 'Advanced -> NC-Base field to match'.
  • Updated Chinese translation.
CIMCO NC-Base 7.01.16
  • Fixed problem with wrong tool list used, when copying programs.
CIMCO Software 7.01.15 PreviewReleased: 11-11-14Register to download
Changes since previous version:
CIMCO Edit 7.01.15
  • Updated Portuguese translation.
  • Fixed translation for macro group.
CIMCO DNC-Max 7.01.15
  • Updated Portuguese translation.
CIMCO Software 7.01.14 PreviewReleased: 07-11-14Register to download
Changes since previous version:
CIMCO Edit 7.01.14
  • Maximizing Editor will no longer cover the Windows taskbar and make it inaccessible if the taskbar is set to auto-hide.
  • Editor Window can now be resized to span multiple monitors.
CIMCO Software 7.01.13 PreviewReleased: 05-11-14Register to download
Changes since previous version:
CIMCO DNC-Max 7.01.13
  • Directory Monitor: Added drag and drop feature for split window.
CIMCO MDC-Max 7.01.13
  • Reports: customizable column titles for variables Machine, Operator, Program, Job
CIMCO NC-Base 7.01.13
  • Added new option: Open files without extension in editor.
  • Removed old setting where extensions in "Machine", "Extensions" was associated with the editor.
  • Fixed problem with Read only function in NCBase running on MSSQL.
CIMCO Software 7.01.12 PreviewReleased: 30-10-14Register to download
Changes since previous version:
CIMCO Edit 7.01.12
  • Backplot/Solid animation: New option to only show decimal numbers for tool dimensions, for example: 8.5 is no longer converted to 17/2.
  • Backplot/Solid animation: Fixed crash when changing between milling and turning, before simulation was started.
  • New tool list generator: Fixed problem with matching tool call, now tool calls have to be preceded by something other than a letter (A-Z).
CIMCO DNC-Max 7.01.12
  • Directory Monitor: Added option to delete files older than one second in send directory when sending a file.
  • Directory Monitor: Fixed crash when trying to connect to an unavailable server.
CIMCO Software 7.01.11 PreviewReleased: 28-10-14Register to download
Changes since previous version:
CIMCO Edit 7.01.11
  • Replace All from file: Fixed problem with browsing files.
CIMCO DNC-Max 7.01.11
  • Fixed problem with missing licenses for Hand Held terminals and Machine Monitors.
CIMCO Software 7.01.10 PreviewReleased: 27-10-14Register to download
Changes since previous version:
CIMCO Edit 7.01.10
  • New feature: Find/replace can now be done using a CSV file with a list of replacements to be performed, the CSV contains two columns the first for search, the second for replace example: T1;T2 T2;T5 Every occurrence of T1 will be replaced with T2, and likewise T2 with T5
  • New Tool list generator: Fixed problem with crashes when distance to comment is equal to max distance.
CIMCO DNC-Max 7.01.10
  • Removed the change from 7.00.19: Program received by DNC is not added on import queue when it is the same.
CIMCO Software 7.01.09 PreviewReleased: 22-10-14Register to download
Changes since previous version:
CIMCO Edit 7.01.09
  • Backplot/Solid Animation: Added ability to define stock for turning.
CIMCO DNC-Max 7.01.09
  • Directory Monitor: Fixed problem with synchronizing FTP root directory.
  • Added option: Disable idle/stopped port, when starting unlicensed port. When this field is checked DNC-Max will automatically disable the first idle/stopped port it finds when the user starts a disabled port and there is no free licenses left, no action is taken if all licensed ports are in use. This option is intended for a single user environment.
CIMCO Software 7.01.08 PreviewReleased: 17-10-14Register to download
Changes since previous version:
CIMCO Edit 7.01.08
  • Added new feature Advanced Renumbering (Beta): Renumbering takes into account commands that use line numbers, such as P and Q.
  • Updated Danish translation.
CIMCO DNC-Max 7.01.08
  • Directory Monitor: Fixed problem with FTP transfers (split screen), and general improvements to FTP performance.
  • Directory Monitor: Synchronize FTP directory with $INCOMING now handles many error scenarios gracefully.
  • Updated Danish translation.
CIMCO Software 7.01.07 PreviewReleased: 13-10-14Register to download
Changes since previous version:
CIMCO MDC-Max 7.01.07
  • Added new type of graph: Log Graph, Log Graph is graphic representation of the Event Log.
  • MTConnect compatibility update.
CIMCO Software 7.01.06 PreviewReleased: 09-10-14Register to download
Changes since previous version:
CIMCO DNC-Max 7.01.06
  • Auto Receive: "Split Siemens .WPD files" now works with receive translators.
CIMCO MDC-Max 7.01.06
  • Protocol configurations updates.
CIMCO NC-Base 7.01.06
  • Added script to perform periodic backup: PeriodicBackup.bat
CIMCO Software 7.01.05 PreviewReleased: 07-10-14Register to download
Changes since previous version:
CIMCO DNC-Max 7.01.05
  • "Send unlocked programs only", "Send programs in database only" and "Only send files in request directories" is now available in both serial and network protocol.
  • Updated auto receive: It can now associate files of the same name to different programs in NC-Base provided they are placed in separate folders.
CIMCO MDC-Max 7.01.05
  • Web Client: Fix issue where live screen status gets stuck.
  • Web Client: Fix inconsistency in ini parsing.
CIMCO Software 7.01.04 PreviewReleased: 03-10-14Register to download
Changes since previous version:
CIMCO Edit 7.01.04
  • Solid animation: Fixed problem with stock collapsing, when updating tools.
  • Updated Mazatrol viewer: Can now view binary files.
CIMCO DNC-Max 7.01.04
  • Added option to clean out NC-Base associated files when auto-receiving a program using a Directory monitor. This will effectively allow having a dynamic list of associated files and/or renaming associated files without having to manually delete the old files from NC-Base. This option is available under 'Auto receive -> Set: 'Name' -> NC-Base -> Delete NCBase associated files on receive'. Please backup files before activating this option.
  • Reworked 'Receive -> Advanced -> Enable multi file reception' in Serial protocols. When using this option, each remote request in the multi request file should now be handled in the same way as if it were made in a file on it's own.
CIMCO Software 7.01.03 PreviewReleased: 01-10-14Register to download
Changes since previous version:
CIMCO Edit 7.01.03
  • Backplot/Solid animation: Fixed problem with saving tool lists.
  • Updated Siemens Control: Fixed IC?AC in turning mode.
  • New Tool list generator: Fixed template for generating HTML tool list.
CIMCO DNC-Max 7.01.03
  • Web Client: Add feature to toggle visibility of machines.
  • Web Client: Fix error when certain file names use invalid encoding.
  • Web Client: Fix error when reading drive information.
CIMCO Software 7.01.02 PreviewReleased: 29-09-14Register to download
Changes since previous version:
CIMCO Edit 7.01.02
  • New Tool list generator: Added template for generating HTML tool list.
  • Updated Fanuc/ISO control: Fixed issue with arc tolerance.
  • Updated Siemens Control: Fixed IC?AC in turning mode.
CIMCO DNC-Max 7.01.02
  • Added option to work with Siemens WPD folder in network monitor and auto receive when main program name does not match with folder name.
CIMCO MDC-Max 7.01.02
  • Increased range limits of speeds and feeds in MDC monitor protocols from 140 to 200.
  • Added option for MySQL server to increase maximum allowed packet size, requires restart of database
  • Added option to adjust button font size on operator panel.
  • Added new feature for operator buttons which can execute a batch command after pressing them.
CIMCO NC-Base 7.01.02
  • Added a new optional feature to keep first version forever as a Master file.
  • Added support for new Tool list generator.
CIMCO Software 7.01.01 PreviewReleased: 22-09-14Register to download
Changes since previous version:
CIMCO Edit 7.01.01
  • Toolpath statistic: Fixed issue with imperial system in Siemens Turning.
CIMCO Software 7.01.00 PreviewReleased: 19-09-14Register to download
Changes since previous version:
CIMCO DNC-Max 7.01.00
  • Serial protocol: Added option to send all NC-Base entries that match, when using Remote Requests with 'Advanced -> NC-Base field to match'.
CIMCO MDC-Max 7.01.00
  • Fixed problem with freezing live screens.
CIMCO Software 7.00.99 PreviewReleased: 18-09-14Register to download
Changes since previous version:
CIMCO Edit 7.00.99
  • Fixed problem where the editor freezes if a file is open on a network share and connection to the network share is lost.
  • Added warning if auto save fails because of unresponsive filesystem or connection to a network share is lost.
  • Backplot/Solid animation: Fixed problem with tools changes tool type after selecting them example: Chamfer Mill becomes Drill.
  • Backplot/Solid animation: Fixed problem in NC-Code with no tool call where backplot forgets the assigned tool, and reverts to the default tool.
CIMCO Software 7.00.98 PreviewReleased: 18-09-14Register to download
Changes since previous version:
CIMCO NC-Base 7.00.98
  • Fixed problem with too few search results caused by "log content search" now it is only used when searcing using "All Fields".
CIMCO Software 7.00.97 PreviewReleased: 16-09-14
Changes since previous version:
CIMCO MDC-Max 7.00.97
  • Option to generate MDC event, when sub screen is opened.
CIMCO Software 7.00.96 PreviewReleased: 12-09-14Register to download
Changes since previous version:
CIMCO Edit 7.00.96
  • Fixed autosave timer values for one hour and up to match their listed values.
  • Updated Danish translation.
CIMCO DNC-Max 7.00.96
  • Fixed bug where autoreceive success reports would be deleted almost immediately after being sent.
  • Changed the way reports for autoreceive success and remote request failures are defined when running a directory monitor setup, previously the autogenerated report filename was set individually for each autoreceive or remote request set. Now, the filename for autogenerated reports is set for the entire port under 'Advanced > Report success' and 'Advanced > Report failed request'. This filename can contain variables such as $RECVPRGNAME to allow for program specific report filenames. The field previously used to set filename for the individual sets can now instead be used to send a specific, pre-generated file to use as report for the specific Autoreceive or Remote request set. Please go through any Autoreceive or Remote request sets to make sure the desired method of error report is selected.
  • Added option to synchronize an FTP directory with a local directory, for use with directory monitor, this option is availabe under 'Advanced > Other' when 'FTP Client' is enabled under the same page. The synchronization interval is configured using "Scan interval" in "Directory Scan", Autoreceive and Remote Request, as well as subfolder synchronization are supported.
  • Updated Danish translation.
CIMCO NC-Base 7.00.96
  • Added option to search log text when using "All Fields" in Advanced search it can be disabled using "Disable log content search".
CIMCO Software 7.00.95 PreviewReleased: 05-09-14Register to download
Changes since previous version:
CIMCO Edit 7.00.95
  • Added new Tool list generator with support for the following new features: * Extracting lines from the NC file and inserting them in the tool list, you can configure: ** Where to place the extracted lines in the tool list file. ** Extract using several different search criteria. ** Using regular expressions when to start and stop extracting. ** How many lines should be extracted. ** Choose to only extract comments. ** Extract the same sequence multiple times. ** Insert line number on each extracted line. ** Filter the extracted lines, with regular expressions. * Generate XML files or other computer readable files. * Change spacing and layout of the tool line. * Extract more than 2 lines of comments for each tool. * Choose how many comment lines is scanned above or below tool. * Choose from where tool comments are selected: Above, Below or Both. * Use different comment symbols * Show comment from the same tool if it is seen multiple times. The features mentioned above is used by editing the new template.
CIMCO Software 7.00.94 PreviewReleased: 29-08-14Register to download
Changes since previous version:
CIMCO Edit 7.00.94
  • Added support for Windows XP when editing ConfigPaths.cfg
  • Updated Swedish and French translation.
CIMCO DNC-Max 7.00.94
  • Updated Swedish and French translation.
CIMCO Software 7.00.93 PreviewReleased: 25-08-14Register to download
Changes since previous version:
CIMCO Edit 7.00.93
  • Fixed problem with importing Types directory to ConfigPahts.cfg when upgrading.
  • Added option to modify ConfigPahts.cfg under Setup: Plugins and "Edit configuration paths".
CIMCO DNC-Max 7.00.93
  • Directory Monitor: Fixed problems with FTP Paths containing backslash.
CIMCO MDC-Max 7.00.93
  • Increased maximum number of MDC clients to 512.
CIMCO Software 7.00.92 PreviewReleased: 19-08-14Register to download
Changes since previous version:
CIMCO Edit 7.00.92
  • Updated Swedish translation.
CIMCO DNC-Max 7.00.92
  • Updated Swedish translation.
  • Updated English and French NC-Base help files.
CIMCO MDC-Max 7.00.92
  • MTConnect protocol variable attributes for alarms.
  • Fixed issue with ordering of Machines in Tables/Graphs/Logs configuration.
CIMCO Software 7.00.91 PreviewReleased: 15-08-14Register to download
Changes since previous version:
CIMCO Edit 7.00.91
  • Added option to automatically exit the editor and save files after a period of inactivity.
  • Fixed issue with R-arcs in MillPlus.
  • Fixed problem with DOS file names in ConfigPahts.cfg.
  • Updated French translation.
CIMCO DNC-Max 7.00.91
  • Updated French translation.
CIMCO MDC-Max 7.00.91
  • Optimized Netlink support.
CIMCO Software 7.00.90 PreviewReleased: 12-08-14Register to download
Changes since previous version:
CIMCO Edit 7.00.90
  • Fixed problem with wrong text on "Automatic stock scanning".
CIMCO NC-Base 7.00.90
  • Added option: "Use id number to avoid conflicting filenames" which only appends unique id when a conflict is detected on associated files.
CIMCO Software 7.00.89 PreviewReleased: 11-08-14Register to download
Changes since previous version:
CIMCO Edit 7.00.89
  • Convert NC Code (Beta): Fixed conversion from ISO.
  • Toolpath statistic: Siemens Turning is now supported (Beta).
  • Improved reading of ConfigPaths.cfg
CIMCO Software 7.00.88 PreviewReleased: 08-08-14Register to download
Changes since previous version:
CIMCO Edit 7.00.88
  • Updated Korean translation.
  • Updated Mazatrol viewer.
  • Convert NC Code (Beta): * Fixed bugs in Heidenhain cycle conversion. * Fixed bug in full - arc convection.
CIMCO MDC-Max 7.00.88
  • Small fix for Heidenain MDC protocol.
CIMCO Software 7.00.87 PreviewReleased: 06-08-14Register to download
Changes since previous version:
CIMCO Edit 7.00.87
  • Updated Automatic stock scanning, changed the keyword to STOCK MIN, and STOCK MAX example: (STOCK MIN X-40 Y-39.286 Z-23.8257 ) (STOCK MAX X40 Y40 Z4.8 ) Heidenhains BLK FORM is still supported.
  • Added new option "Update stock definition in NC file", it adds STOCK MIN and STOCK MAX to the top of the file, if the machine type is Heidenhain BLK FORM is used instead.
  • Added ISO Milling (Inverse Z), with support for Z-axis inversion.
  • Fixed missing fields in Tool path statistics (Turning).
  • Fixed problem running Convert NC Code (Beta).
  • Updated Heidenhain New: * M128/129 fixed * ToolDirection mode available
CIMCO Software 7.00.86 PreviewReleased: 01-08-14Register to download
Changes since previous version:
CIMCO Edit 7.00.86
  • Added feature in NC-Assistant: Selected macros and macro groups is now associated with the current file instead of current machine.
  • NC-Assistant: Fixed find macro.
  • NC-Assistant: Fixed selection of macros being shown in NC Assistant when selecting them in the NC file.
CIMCO Software 7.00.85 PreviewReleased: 29-07-14Register to download
Changes since previous version:
CIMCO Edit 7.00.85
  • Convert NC Code (Beta): * Added/improved support for 20 cycles. * Improvements in cycles conversion, added option for conversion cycles to longhand.
  • Updated Fanuc/ISO control: Rounding (,R syntax) supports now line-circle connection in both directions.
CIMCO MDC-Max 7.00.85
  • Added feature to prevent start of windows screen saver in full screen.
CIMCO Software 7.00.84 PreviewReleased: 23-07-14
Changes since previous version:
CIMCO Edit 7.00.84
  • Added better support for migrating configuration to AppData.
CIMCO Software 7.00.83 PreviewReleased: 23-07-14Register to download
Changes since previous version:
CIMCO Edit 7.00.83
  • New Heidenhain (Beta): Fixed tool change problem, added tolerance setting (CYCL DEF 32).
  • Updated Fanuc/ISO control: * Fixed formula interpretation. * Fixed rounding and chamfering. * Fixed interpretation of A, C and R values. * Fixed X100 = X0.1 option. * Fixed G71 internal roughing.
  • Made parsing of ConfigPaths.cfg more robust.
CIMCO Software 7.00.82 PreviewReleased: 22-07-14Register to download
Changes since previous version:
CIMCO Edit 7.00.82
  • New Heidenhain (Beta): Tangential approach in cycles, enable text labels.
CIMCO CNC-Calc 7.00.82
  • Corrected error for splines with a degree higher than 3. These still can not be read but the program should not crash when they exists in a loaded DXF file.
CIMCO DNC-Max 7.00.82
  • Added buttons "Select All" + "Select None" in DNC backup restore dialog.
CIMCO MDC-Max 7.00.82
  • Fixed waiting for NETLink start-up.
  • Fixed reading active program on Heidehain TNC 430/426
  • Added support to have an extra cycle time switching from high to low state and from low to high state
  • Fixed problem with time line because of auto-update during midnight.
  • Improved performance of time line live update.
  • Fixed MDC client -> dragged mouse move on standard graph.
  • Improved dialog selector to see longer MDC equations.
  • Fixes for losing of MDC configuration.
CIMCO Software 7.00.81 PreviewReleased: 04-07-14
Changes since previous version:
CIMCO Edit 7.00.81
  • Fixed bug with macros when creating file types.
  • Changed the default placement of all configuration files to the users AppData directory, this can be configured using the file: ConfigPaths.cfg PLEASE NOTE If you have multiple installations on the same PC and need separate configurations: Edit ConfigPaths.cfg and change ROOTDIR to: ROOTDIR = %EXEDIR% or change ROOTDIR to a unique directory for each installation.
  • The following options in the configuration are replaced by ConfigPaths.cfg: * "Share settings between all users" * "Configuration file path" ConfigPaths.cfg syntax explained ================================ Text after '#' is ignored as comment. Variables is defined like this: VARIABLE = [path] You can reuse a variable by placing '%' around it like so: %VARIABLE% '%' is only allowed for variables, directories containing '%' are invalid. Special variables: %VENDORDIR% resolves to "[vendor]" %PRODUCTDIR% resolves to "[program name][major version]" %EXEDIR% resolves to "[path to program.exe]" Windows environment variables are resolved after the special variables example: %APPDATA% resolves to "C:\Users\[username]\AppData\Roaming" Required variables: ROOTDIR, CFG, DATA, MACHINES, TYPES, TOOLLIBS, LOG Default values: ROOTDIR = %APPDATA%\%VENDORDIR%\%PRODUCTDIR% CFG = %ROOTDIR%\Cfg DATA = %ROOTDIR%\Data MACHINES = %ROOTDIR%\Machines TYPES = %ROOTDIR%\Types TOOLLIBS = %ROOTDIR%\ToolLibs LOG = %ROOTDIR%\Log
CIMCO Software 7.00.80 PreviewReleased: 30-06-14Register to download
Changes since previous version:
CIMCO Edit 7.00.80
  • Fixed potential crash when closing the editor.
CIMCO DNC-Max 7.00.80
  • Remote request: Added new option: Include NC-Base programs with extensions The specified extensions will be used to look up programs with same base name, requires NC-Base and Associated files set to: "Use NC-Base". Example: Requested NC-Base program "O1234" NC-Base contains two programs: O1234.MPF and O1234.SPF, if the field contains "MPF,SPF", both O1234.MPF and O1234.SPF will be send. This works similar to subprograms in NC-Base.
CIMCO MDC-Max 7.00.80
  • Fixed timer value TIMERLAST counting even if it is suspended.
  • Added vertical scroll with mouse on timeline.
CIMCO Software 7.00.79 PreviewReleased: 25-06-14Register to download
Changes since previous version:
CIMCO Edit 7.00.79
  • Fixed bug when creating new machines.
  • Backplot/Solid animation: Fixed bug in tool scan.
CIMCO DNC-Max 7.00.79
  • Improved performace with MSSQL
  • Added new feature in Directory monitor auto receive: Update file modify time if files are identical.
  • Directory monitor Auto receive: Disabled "Save in $INCOMING" it is only implemented in serial protocol.
CIMCO MDC-Max 7.00.79
  • Fixed MTConnect agent running multiple times.
  • Netlink feed rate / rapid feed updates.
CIMCO Software 7.00.78 PreviewReleased: 20-06-14Register to download
Changes since previous version:
CIMCO Edit 7.00.78
  • Convert NC Code (Beta): Support sub-programs repeats (L), improved R-arcs conversion.
  • New Heidenhain (Beta): Bug in drilling cycles fixed.
CIMCO MDC-Max 7.00.78
  • Added horizontal scroll using mouse move in time line.
  • Support generating reports for machine groups (MDC groups, NCBase groups, DNC groups)
  • Automatic update of time line when crossing midnight.
  • NETLink updates, MTConnect updates.
CIMCO Software 7.00.77 PreviewReleased: 18-06-14Register to download
Changes since previous version:
CIMCO CNC-Calc 7.00.77
  • It is now possible to delete parameter sets in the load and save parameter dialogues.
  • In contour milling tool will now retract to retract height between contours, previously it only retracted to the safe distance.
CIMCO MDC-Max 7.00.77
  • Fixed problem with connecting multiple MDC-Max clients to DNC-Max server.
CIMCO Software 7.00.76 PreviewReleased: 17-06-14Register to download
Changes since previous version:
CIMCO Edit 7.00.76
  • NC-Functions: Fixed mirroring Heidenhain. * Fixed linearisation while mirroring. * Fixed G17/18 arcs while mirroring with angle +(-)45.
CIMCO CNC-Calc 7.00.76
  • Drilling now defaults to the last used operation type.
  • When selecting contours ghost circles should no longer be shown.
CIMCO Software 7.00.75 PreviewReleased: 16-06-14Register to download
Changes since previous version:
CIMCO Edit 7.00.75
  • Updated Finnish translation.
CIMCO CNC-Calc 7.00.75
  • Error with the milling of true type fonts corrected. The error happened quite seldom, but made it impossible to mill select letters.
CIMCO DNC-Max 7.00.75
  • Updated Finnish translation.
CIMCO Software 7.00.74 PreviewReleased: 12-06-14Register to download
Changes since previous version:
CIMCO Edit 7.00.74
  • Enabled loop in Solid Animation.
CIMCO DNC-Max 7.00.74
  • DNC-Max auto receive: Added option to recursively search the auto receive directory for the received filename and replace the first file found with the same name.
CIMCO MDC-Max 7.00.74
  • Fixed issue with remapping of messages from MDC client.
CIMCO Software 7.00.73 PreviewReleased: 10-06-14Register to download
Changes since previous version:
CIMCO Edit 7.00.73
  • Backplot/Solid animation: Added New Heidenhain (Beta) control, be aware that there can be issues with the control.
  • NC-Functions: Added new module NC Converter (Beta), that uses a post processor to generate the NC code, be aware that there can be issues with the conversion, the following operations is supported: * Heidenhain to ISO/Fanuc * ISO/Fanuc to Heidenhain
  • NC-Functions: Fixed mirroring Heidenhain.
CIMCO CNC-Calc 7.00.73
  • Sometimes Contour milling wouldn't produce any toolpath if the the number of roughing steps was 0 but the Roughing Stepover was larger than the Finish Stepover. Now the Roughing Steopover is ignored if the number of roughing steps are 0.
  • It is still not possible to make toolpaths where the roughing stepover is larger than the finish stepover (why would anyone do that?).
  • When 'Use Sidecuts' are unchecked the one side cut that are made will be a finish cut. That means that the 'Compensation Type' will be used. That is also the reason that the 'Finish Overlap' is now enabled and will be used even when 'Use Sidecuts' are disabled.
CIMCO Software 7.00.72 PreviewReleased: 06-06-14Register to download
Changes since previous version:
CIMCO CNC-Calc 7.00.72
  • Since Helix Substitution is now supported in the Post Processors (where they are pertinent) they have been removed from the parameter dialogues for the operations Pocket Milling, Contour Milling, Helix Milling and Thread Milling.
  • The parameter 'Stay Down Distance' has been added to the Contour Milling parameters. This parameter controls how linking is performed between exit and entry points, if the distance between the exit and entry points are longer than the stay down distance, the tool will make a retract move before moving between the two points. In order to ensure that the tool will retract you can set the Stay Down Distance to 0.0.
CIMCO Software 7.00.71 PreviewReleased: 05-06-14Register to download
Changes since previous version:
CIMCO Edit 7.00.71
  • Fixed problem with 5-Axis configuration.
CIMCO Software 7.00.70 PreviewReleased: 05-06-14Register to download
Changes since previous version:
CIMCO Edit 7.00.70
  • Fixed paste inserting extra line.
CIMCO MDC-Max 7.00.70
  • Fixed issue with remapping and messages from buttons.
  • Fixed problem when input is given by bar-code reader.
  • Fixed feature for remapping messages: Now one message can be remapped into more messages if conditions are true.
CIMCO NC-Base 7.00.70
  • Added option: "Server Settings" > "Backup machine group changes" it logs each change to associations between machine groups and DNC-Max ports.
  • Maintenance: Added ability to restore association between machine groups and DNC-Max ports using the log, this can be used to recover from instances where DNC-Max changes port id's.
CIMCO Software 7.00.69 PreviewReleased: 03-06-14Register to download
Changes since previous version:
CIMCO Edit 7.00.69
  • Updated copy/paste.
  • Fanuc/ISO control: Fixed arc detection.
CIMCO Software 7.00.68 PreviewReleased: 30-05-14Register to download
Changes since previous version:
CIMCO Edit 7.00.68
  • Solid Animation (New OpenGL): Fixed problems with switching between milling and turning.
  • Solid Animation and Backplot: Go to first line when switching between milling and turning.
CIMCO Software 7.00.67 PreviewReleased: 28-05-14Register to download
Changes since previous version:
CIMCO CNC-Calc 7.00.67
  • Error with parameter validation in contour milling has been corrected.
CIMCO NC-Base 7.00.67
  • Added option to save using Sub-program extension, when using "Save As".
  • Added ability to change extension of files when creating new programs, the allowed extensions is taken from the Sub-program extension list.
CIMCO Software 7.00.66 PreviewReleased: 27-05-14Register to download
Changes since previous version:
CIMCO Edit 7.00.66
  • Fixed problem with CNC-Calc, Mazatrol Viewer with demo license.
  • Updated French translation.
  • Updated Danish CNC-Calc help file.
CIMCO DNC-Max 7.00.66
  • Updated French translation.
CIMCO MDC-Max 7.00.66
  • Added a filter for top predefined number of values showed in a graph.
CIMCO NC-Base 7.00.66
  • Added options to unlink or delete all DNC-Max ports in the NC-Base.
CIMCO Software 7.00.65 PreviewReleased: 23-05-14Register to download
Changes since previous version:
CIMCO Edit 7.00.65
  • Toolpath statistics: Fixed dwell time calculations.
  • Fanuc turning: Added support for "X100 = X0.100".
CIMCO Software 7.00.64 PreviewReleased: 22-05-14Register to download
Changes since previous version:
CIMCO Edit 7.00.64
  • Fanuc turning: * Fixed problem with G71 and G04. * Fixed problem with G95 command was able to block current movement command.
CIMCO MDC-Max 7.00.64
  • Speeded up of rebuild/calculation when MSSQL is used.
CIMCO Software 7.00.63 PreviewReleased: 20-05-14
Changes since previous version:
CIMCO Edit 7.00.63
  • Fixed problem with moving macros.
CIMCO Software 7.00.62 PreviewReleased: 20-05-14Register to download
Changes since previous version:
CIMCO Edit 7.00.62
  • Toolpath statistics: Dwelling time is being added to total machining time.
  • Fanuc/ISO control: Added option to ignore block skip.
CIMCO Software 7.00.61 PreviewReleased: 20-05-14
Changes since previous version:
CIMCO Edit 7.00.61
  • Fixed problem with creating new macros.
CIMCO Software 7.00.60 PreviewReleased: 19-05-14Register to download
Changes since previous version:
CIMCO Edit 7.00.60
  • Toolpath statistics: Added units/min and units/rev to turning.
  • Fixed problem with ordering macros.
  • Fanuc turning: Fix for possible problems with "ignore M6" option.
CIMCO CNC-Calc 7.00.60
  • Added new post processor: heidenhain DE
CIMCO Software 7.00.59 PreviewReleased: 15-05-14Register to download
Changes since previous version:
CIMCO Edit 7.00.59
  • Fanuc/ISO control: Fixed arc detection.
CIMCO CNC-Calc 7.00.59
  • The contour operation now performs a full retract between individual contours. Previously it would stay down while travelling between some contours placed close together.
CIMCO Software 7.00.58 PreviewReleased: 14-05-14Register to download
Changes since previous version:
CIMCO Edit 7.00.58
  • Added new feature: Macro Groups, macros can now be ordered in groups. * All macros start in the initial group "Default". * Added a new button "Move To", for moving macros between machines and macro groups. * You can select macro groups in the NC-Assistant or in the menu bar.
  • Updated Mazatrol viewer.
  • Updated solid animation: Fixed tools in Heidenhain.
  • Updated manifests to support: Vista, 7, 8, 8.1
CIMCO DNC-Max 7.00.58
  • Updated DNC-Max Web client.
  • Updated manifests to support: Vista, 7, 8, 8.1
CIMCO Software 7.00.57 PreviewReleased: 12-05-14Register to download
Changes since previous version:
CIMCO Edit 7.00.57
  • Updated Mazatrol viewer.
  • Updated solid animation (New OpenGL): Fixed tools in Heidenhain.
CIMCO Software 7.00.56 PreviewReleased: 09-05-14Register to download
Changes since previous version:
CIMCO Edit 7.00.56
  • Fixed problem with next/prev tool change in Heidenhain where the tool call uses quotes: TOOL CALL "SF16" Z S1500
  • Updated solid animation (New OpenGL): Fixed coordinate system axes lines bug.
  • Improved floating licences for CNC-Calc and Mazatrol Viewer.
CIMCO CNC-Calc 7.00.56
  • Added Post Processor Manual.
  • Added post processor for: Deckel Dialog 2-4 Linar Helix.
  • Added support for Text height in measurement text.
CIMCO DNC-Max 7.00.56
  • Network Protocol: Fixed FTP client.
  • Updated DNC-Max Web client.
CIMCO MDC-Max 7.00.56
  • MTConnect: Added option for generating message "part count" only in AUTOMATIC mode.
CIMCO Software 7.00.55 PreviewReleased: 05-05-14Register to download
Changes since previous version:
CIMCO CNC-Calc 7.00.55
  • Added support for contouring.
CIMCO NC-Base 7.00.55
  • Added option for a machine to share with more than 4 machine groups.
CIMCO Software 7.00.54 PreviewReleased: 30-04-14Register to download
Changes since previous version:
CIMCO Edit 7.00.54
  • Updated German, French and Korean translation.
  • Updated Czech Edit help.
CIMCO DNC-Max 7.00.54
  • Updated German, French and Korean translation.
CIMCO MDC-Max 7.00.54
  • Added parameter QUERYTIMEOUT solving issue with MSSQL when it contains lots of collected data.
  • Fixed hanging MDC client when report configuration is changed and live screen is not open.
CIMCO Software 7.00.53 PreviewReleased: 23-04-14Register to download
Changes since previous version:
CIMCO Edit 7.00.53
  • Updated Finnish translation.
  • Updated German help.
  • Fanuc: Added support for G22/G23 helix commands similar to Fidia C20 control.
  • APT: Fixed multi-turn helix.
  • Solid simulation: Treading tool entering cut and exiting cut improved.
  • Solid simulation: Support of non-convex geometry of the tool.
  • Solid simulation: Fixed blinking Rotate button.
  • Solid simulation: Fixed rare bug with wrong visual tool representation.
CIMCO DNC-Max 7.00.53
  • Updated Finnish translation.
  • Network Protocol: Fixed translator in remote request.
CIMCO MDC-Max 7.00.53
  • Fixed MDC hanging.
CIMCO Software 7.00.52 PreviewReleased: 16-04-14Register to download
Changes since previous version:
CIMCO Edit 7.00.52
  • Fanuc (A, B, C), Turning ISO, Traub and Haas: Arc detection and tiny arc bug are fixed in turning modes.
  • Solid simulation: Entering and Exit cut patterns in treading simulation partially fixed.
CIMCO NC-Base 7.00.52
  • Renaming a program will give associated files unique names, and copy linked files if "Add id number to associated/other/picture filenames" is set.
  • Updated method of generating unique id when associating files if "Add id number to associated/other/picture filenames" is set.
CIMCO Software 7.00.51 PreviewReleased: 15-04-14Register to download
Changes since previous version:
CIMCO Edit 7.00.51
  • NC Functions: Fixed arcs defined by radius don't change to arcs defined by center.
  • Fanuc control: G32 and G76 treading fix, and changed lead-out behaviour.
  • Fixed problem with Fanuc jumping to ISO.
CIMCO DNC-Max 7.00.51
  • Implemented passive mode for FTP server port.
CIMCO Software 7.00.50 PreviewReleased: 11-04-14Register to download
Changes since previous version:
CIMCO Edit 7.00.50
  • Solid simulation: Added threading support for the following codes in threading: * Fanuc G32, G92, G76 * Siemens, Traub and Haas CYCLE97, L97
CIMCO DNC-Max 7.00.50
  • Updated DNC-Max Web client.
CIMCO Software 7.00.49 PreviewReleased: 10-04-14Register to download
Changes since previous version:
CIMCO Edit 7.00.49
  • Fanuc turning: Complete support of G32 treading cycle.
  • NC-Functions updated: * New mirror/rotate does not modify a number of non-changeable commands.
CIMCO DNC-Max 7.00.49
  • Added feature for multiple scans when bar-code reader is connected to hand-held terminal
  • Added feature for programs received via split screen if export to NC-Base is active, programs are copied to the INCOMING folder first.
  • Improved speed of LSV2 protocol in split window.
CIMCO MDC-Max 7.00.49
  • Added feature to accept environment variable for machine name in time line ($MCHVARTEXT1, $REPORTMACHINEGROUPMDC...)
  • Added support for a new firmware of NETLink Compact PRO.
CIMCO NC-Base 7.00.49
  • Fixed Open: Fixed problem with files always opening in editor.
CIMCO Software 7.00.48 PreviewReleased: 07-04-14Register to download
Changes since previous version:
CIMCO Edit 7.00.48
  • Backplot/Solid animation: Fixed misinterpretation of E parameter as standard scientific notation for a number.
  • Updated Polish translation.
CIMCO DNC-Max 7.00.48
  • Added support for waiting time in-between multiple scans can be done with a barcode reader.
  • Updated Polish translation.
CIMCO Software 7.00.47 PreviewReleased: 02-04-14Register to download
Changes since previous version:
CIMCO Edit 7.00.47
  • NC-Functions updated: * Made the old method of mirror and rotate default, added option to use new method.
CIMCO CNC-Calc 7.00.47
  • It is now possible to print a screen capture from CNC-Calc. All content in the Graphic drawing area will be printed to a selected printer when the Print button in CNC-Calc's tool ribbon is pressed.
CIMCO NC-Base 7.00.47
  • Fixed Open: Open with editor if the extension matches the machine group extension, or the file and machine group extension are both empty.
CIMCO Software 7.00.46 PreviewReleased: 31-03-14Register to download
Changes since previous version:
CIMCO Edit 7.00.46
  • NC-Functions updated: * Fixed X,Y output within cycles. * Fixed C,H,E output.
  • Added digital signature to programs, this improves support for windows.
  • Updated Czech, German and Japanese translation.
CIMCO DNC-Max 7.00.46
  • Updated Czech, German and Japanese translation.
  • Added digital signature to programs, this improves support for windows.
CIMCO Software 7.00.45 PreviewReleased: 25-03-14Register to download
Changes since previous version:
CIMCO Edit 7.00.45
  • Fixed colors in tool preview.
CIMCO CNC-Calc 7.00.45
  • It is now possible to add measurements to a CNC-Calc drawing.
CIMCO Software 7.00.44 PreviewReleased: 24-03-14Register to download
Changes since previous version:
CIMCO Edit 7.00.44
  • Fanuc: Infinite loop interruption in WHILE and GOTO commands for Fanuc is made more strict
  • Files with long paths in recent file list is now trimmed so the file name is visible.
  • Updated Czech, French and Danish translation.
CIMCO MDC-Max 7.00.44
  • Optimized memory usage of MDC client.
CIMCO Software 7.00.43 PreviewReleased: 14-03-14Register to download
Changes since previous version:
CIMCO Edit 7.00.43
  • Add option to open files with wrapped lines read only.
  • External commands: Added variable $NCBASEFULLPATH with the full path to the file in NC-Base, Warning! Modifying this file can potentially corrupt the NC-Base.
  • Fanuc: Fixed additional shift table for G54 and G54.1 with P parameter.
  • Updated English and French Edit help file.
CIMCO Software 7.00.42 PreviewReleased: 12-03-14Register to download
Changes since previous version:
CIMCO Edit 7.00.42
  • Updated integration with Mastercam.
CIMCO CNC-Calc 7.00.42
  • Fixed errors with reading splines in DXF.
CIMCO Software 7.00.41 PreviewReleased: 10-03-14Register to download
Changes since previous version:
CIMCO Edit 7.00.41
  • Solid simulation: (New GL) Added feature: When you press Zoom/Regenerate stock you can precisely select which part of the stock that should be shown.
CIMCO DNC-Max 7.00.41
  • Fixed export to NC-Base for FTP protocol.
CIMCO MDC-Max 7.00.41
  • Changed XML format of "Export To XML" this prevents invalid XML.
CIMCO Software 7.00.40 PreviewReleased: 07-03-14Register to download
Changes since previous version:
CIMCO CNC-Calc 7.00.40
  • It is now possible to use splines and to produce toolpath for these. The splines can either be imported from dxf files or drawn directly in CNC-Calc. When a toolpath is generated the splines will be converted to line segments. The size of these line elements are configurable in the CNC-Calc setup, the finer this tolerance is set the longer the NC program will be since a fine tolerance will result in a larger number of line segments. When splines are drawn in CNC-Calc the tangency of lines and circles can be used to set the start and end conditions (tangency) of the spline. In order to use this feature turn on the 'Snap to End Poits' snap. When an endpoint of an arc or a line is selected a dialog box will open and it is now possible to select if the end conditions of the arc/line should be used to set the start or end condition of the spline.
CIMCO MDC-Max 7.00.40
  • New feature for IOLogic device: Detection of blinking signal.
  • Implemented support for IOLogic devices with password.
CIMCO Software 7.00.39 PreviewReleased: 28-02-14Register to download
Changes since previous version:
CIMCO Edit 7.00.39
  • Fanuc: G71 for internal roughing is fixed.
  • Added TeamViewer support client.
CIMCO DNC-Max 7.00.39
  • Fixed auto receive for network protocols (LSV2/FTP/FOCAS).
  • Fixed export on import queue for network protocols (LSV2/FTP/FOCAS).
  • Added TeamViewer support client.
CIMCO MDC-Max 7.00.39
  • Fixed issue with loosing focus on event log list when time, machine, or message filter is used.
  • Added feature: Events given by MDC client operator panel go through DNCMaxOEMLink.dll
CIMCO Software 7.00.38 PreviewReleased: 26-02-14Register to download
Changes since previous version:
CIMCO Edit 7.00.38
  • NC-Functions: Re-enabled Heidenhain support for Mirror and Rotate.
CIMCO DNC-Max 7.00.38
  • NETLink adapter: Feed hold signal fixed/tested.
CIMCO NC-Base 7.00.38
  • "Add id number to other filenames" and "Add id number to picture filenames" is now performed when copying programs with associated files.
CIMCO Software 7.00.37 PreviewReleased: 24-02-14Register to download
Changes since previous version:
CIMCO Edit 7.00.37
  • Increase global password length from 16 to 256 chars.
CIMCO DNC-Max 7.00.37
  • Increase global password length from 16 to 256 chars.
  • Added support for hand-held terminal for directory monitor port.
  • Remote request: Allow directory delimiters: '\', '/' in file names.
CIMCO MDC-Max 7.00.37
  • Added function for importing reports from a mmr configuration file.
  • Input field extracts value processed by advanced trigger to VAR3.
  • Added option to select a time range for MDC events displayed in MDC client in event log.
  • Web Client: Fix bug that caused the MDC server to not respond.
  • Web Client: Minor changes to visuals.
  • Web Client: Add service to monitor if HTTP is up.
CIMCO Software 7.00.36 PreviewReleased: 20-02-14Register to download
Changes since previous version:
CIMCO Edit 7.00.36
  • APT, Deckel, Emco, Fagor, Heidenhain ISO, Mach3, Fanuc Robot * Problem with arcc set using R value fixed.
  • Fanuc: * Polar coordinates fix for canned cycles. * Fixed bug with wrong feed rate information G92 treading cycle was sending to time estimation module.
CIMCO DNC-Max 7.00.36
  • Directory Monitor: Fixed problem with NC-Base integration and FTP Receive.
CIMCO MDC-Max 7.00.36
  • MTConnect: * Support machine part counter. * Added option for generating CYCLE ON when machine part counter is changed.
  • NETLink PRO Compact adapter: Added support for Feed Hold signal.
  • Fixed printing of Log tables.
CIMCO Software 7.00.35 PreviewReleased: 14-02-14Register to download
Changes since previous version:
CIMCO Edit 7.00.35
  • Tool path statistics (Turning): * Fixed several minor bugs in time calculation. * Supported statistics data output extended to full amount.
  • APT, Deckel, Emco, Fagor, Heidenhain ISO, Mach3, Fanuc Robot: * Fixed bug in corner rounding function. * Fixed bug in the linear shift of coordinate system.
  • Updated French translation.
  • CNC-Calc help updated.
CIMCO CNC-Calc 7.00.35
  • Updated Deckel and Heidenhain post processors.
CIMCO DNC-Max 7.00.35
  • Directory Monitor: Added extra checks when transferring files using FTP.
CIMCO Software 7.00.34 PreviewReleased: 10-02-14Register to download
Changes since previous version:
CIMCO Edit 7.00.34
  • Toolpath statistics: Fixed problem with saving feed rate and path unit.
CIMCO Software 7.00.33 PreviewReleased: 07-02-14Register to download
Changes since previous version:
CIMCO Edit 7.00.33
  • Adjust Feed & Speed and Simple Math Functions: Added option to save result to new window.
  • Statistics module for turning is rewritten from scratch: * All CSS values supported, including Maximum Spindle Speed and setting Surface Speed value both for metric and imperial units.
  • Solid Animation (New GL): Temporarily removed feature added in 7.0.31
CIMCO CNC-Calc 7.00.33
  • Fixed problem with Heidenhain post.
CIMCO DNC-Max 7.00.33
  • Added option to disable/enable file filter in CNC window.
  • Removed extension NC in FOCAS CNC window.
  • Fixed refresh of split window when a file is received by FTP client split window.
  • Fixed FOCAS DNC - added processing by auto receive.
  • Setup sheet improved, there were more same options but for different protocols but only one protocol can be active at a time.
CIMCO MDC-Max 7.00.33
  • Added function ping before running HedienhainOCX + terminate OCX when machine doesn't answer on ping.
  • Fixed HeidenhainOCX restart when no free handle is available.
  • Updated HeidenhainOCX.
  • Added new protocol for NetlinkPro HW allowed reading MDC signals from Siemens Sinumerik 840D.
  • Fixed auto close default value.
  • Fixed problem with operator screen without any button.
CIMCO Software 7.00.32 PreviewReleased: 06-02-14Register to download
Changes since previous version:
CIMCO Edit 7.00.32
  • Fixed problem with tiny arcs in Fanuc Turning (Code A,B and C).
  • NC Functions updated: * Fixed some output errors (F,S,Q,R).
CIMCO DNC-Max 7.00.32
  • Fixed problem with missing notification when end trigger is missing.
CIMCO NC-Base 7.00.32
  • Fixed problem with associating files.
CIMCO Software 7.00.31 PreviewReleased: 03-02-14Register to download
Changes since previous version:
CIMCO Edit 7.00.31
  • NC Functions updated: * Added option to copy the result to new window for the following functions: Rotate, Mirror, Tool Compensation, Translate, Heidenhain / ISO Converter.
  • Added better support for Heidenhain when generating Tool List.
  • Updated Mazatrol viewer.
  • Fixed problem with wrong calculation of 5D trajectory, the following filters was affected: APT, Deckel, Emco, Fagor, Heidenhain ISO, Hurco, Mach3, Fanuc Robot.
  • Solid simulation: (New GL) Added New feature: When you press Zoom/Regenerate stock you can precisely select which part of the stock that should be shown.
CIMCO CNC-Calc 7.00.31
  • It is now possible to save parameter sets in CNC-Calc. All the operation Parameter dialog has been changed so they have a "Save Parameters", "Load Parameters" and a "Reset" Button. * Save Parameters: Makes it possible to save a parameter set. * Load Parameters: Loads a parameter set. * Reset: resets the parameter values to the values they had when the parameter dialog was opened.
  • In the new Mill Post Processors the first move will be split in two moves. One in the XY plane and one Z move.
  • The default behaviour is that the first move is made in the XY-plane but this can be changed by setting the variable xyFirstMove in the globals section to false. If xyFirstMove is set to false the first move will be in the Z direction and the second in the XY-Plane.
CIMCO Software 7.00.30 PreviewReleased: 27-01-14Register to download
Changes since previous version:
CIMCO Edit 7.00.30
  • Added function to verify the colors in Machine Template and Backplot.
CIMCO DNC-Max 7.00.30
  • Updated MDC-Max Web client. * Fix stuck colors on live screens. * Fix black color showing as red on live screens. * Stability improvements in server component.
CIMCO Software 7.00.29 PreviewReleased: 21-01-14Register to download
Changes since previous version:
CIMCO Edit 7.00.29
  • Fanuc control: Added support for G-command index calculation. Now you can write something like this: #101 = -1 #102 = 1 G[#101+#102] X0 Y0 Z0 G[#101+#102] X10 G[#101+2*#102] Y10
CIMCO CNC-Calc 7.00.29
  • Previously the "forceDecimals" flag has been used to ensure trailing zeros in the output. Now a new flag "minDecimals" has been implemented. This flag is used.to indicate the lowest number of decimals that should be shown in a decimal number. So the call: xyzFormat = createFormat({decimals: 3, minDecimals: 2}); Will output the values: 3.0 as 3.00 and 4.5 as 4.50
CIMCO DNC-Max 7.00.29
  • DNC-Max Server: Added option to configure FTP Server port.
  • Fixed issues relating to the new feature: Caching of NC-Base configuration.
CIMCO Software 7.00.28 PreviewReleased: 17-01-14Register to download
Changes since previous version:
CIMCO DNC-Max 7.00.28
  • Fixed problem with NC-Base server.
CIMCO Software 7.00.27 PreviewReleased: 16-01-14
Changes since previous version:
CIMCO Edit 7.00.27
  • Tool list: Added new feature to filter comments using regular expression.
CIMCO DNC-Max 7.00.27
  • Added feature for caching of NC-Base server configuration, gives faster start up with slow network connections.
CIMCO NC-Base 7.00.27
  • Fixed problem with copying programs with associated files, by generating a new name for them if the associated files already exists in the destination directory. Enable this by checking: Server Settings > Advanced > "New Setup/Tool/Memo file on copy".
CIMCO Software 7.00.26 PreviewReleased: 10-01-14Register to download
Changes since previous version:
CIMCO Edit 7.00.26
  • Updated Portuguese and French translation.
  • Updated English, French, Swedish, and Danish CNC-Calc help file.
  • Fixed spelling errors in Macros.
  • NC Functions updated: * Re-enabled Strip trailing 0's
CIMCO CNC-Calc 7.00.26
  • Updated Fanuc post processor: Drilling corrected in the Fanuc post processor. The calculated depth and safe distance was not calculated correctly. The new Fanuc post processor generates drilling cycles like version 6.
  • New feature in post processor: A new configuration flag has been added in the call to the function createFormat. CNC-Calc post processors. When the forceDelim flag is set to true it ensures that a '.' is inserted at the end of the output value even if this doesn't have any decimals. "So 3.000" will be output as "3." The default value for the flag forceDelim is true but it can be changed to false in the call to createFormat as shown below: xyzFormat = createFormat({decimals: 3, forceDelim: false});
CIMCO DNC-Max 7.00.26
  • Updated Portuguese and French translation.
  • Updated English, French, Spanish, and German DNC-Max user guide.
  • Added French help for Web Clients, DNC-Max as a service and License server.
CIMCO Software 7.00.25 PreviewReleased: 06-01-14Register to download
Changes since previous version:
CIMCO Edit 7.00.25
  • NC Functions updated: * Fixed crash with some selections.
CIMCO DNC-Max 7.00.25
  • Fixed default file filter in split file window to see all files, even without extension.
CIMCO MDC-Max 7.00.25
  • Fixed issue with reconnecting of HeidenhainOCX.
  • New FOCAS features - read up to 3 macros, every macro has 2 values.
CIMCO Software 7.00.24 PreviewReleased: 27-12-13Register to download
Changes since previous version:
CIMCO Edit 7.00.24
  • Re-enabled ISO Mill/Turn as the default for all filters except ISO.
  • NC Functions updated: * Prints all decimals specified.
CIMCO Software 7.00.23 PreviewReleased: 20-12-13Register to download
Changes since previous version:
CIMCO Edit 7.00.23
  • Updated Mazatrol viewer: Many small fixes.
  • NC Functions updated: * Added support for splitting arcs defined by R.
CIMCO MDC-Max 7.00.23
  • Added auto close function for operators panels (0=deactivate, >0=time in (s)).
  • Fixed refresh of live pie charts running over long term period.
CIMCO Software 7.00.22 PreviewReleased: 19-12-13Register to download
Changes since previous version:
CIMCO Edit 7.00.22
  • NC Functions updated: * Better support for sub programs (M98).
  • Updated Korean translation.
  • Solid simulation: Changed the size of the XYZ arrows.
CIMCO DNC-Max 7.00.22
  • Updated Korean translation.
  • Directory Monitor: Directory Scan Add variable $DBFIELD1 to $DBFIELD9 from the NC-Base when Rename file mode: is set to "Use specified format".
CIMCO Software 7.00.21 PreviewReleased: 17-12-13Register to download
Changes since previous version:
CIMCO Edit 7.00.21
  • NC Functions updated: * Improvements to Mirror and Rotate. * Reverse trajectory now supported. * Added option to specify arc break tolerance.
  • Updated Swedish translation.
CIMCO DNC-Max 7.00.21
  • Updated Swedish translation.
  • Directory Monitor: Enabled Scan Interval to be as low as 10 seconds.
CIMCO Software 7.00.20 PreviewReleased: 13-12-13Register to download
Changes since previous version:
CIMCO Edit 7.00.20
  • Siemens control: Multiple bug-fixes and general speed-up.
  • Fanuc control: * Turning cycle G76 (Multiple threading cycle) is working. * Turning cycle G71 Swiss turret orientation is taken into account during retract calculation. * M98 command now reads Q value. * General speed-up.
  • Heidenhain ISO control: Fixed bug with empty window.
  • NC Functions updated: * Rotation bug fixed. * G18 and G19 arcs are preserved in case of 0, 90, 180 and 270 angle. (new feature). * Fixed bugs related to G41 G42.
  • Updated Danish, French and English translation.
CIMCO DNC-Max 7.00.20
  • Updated Danish, French and English translation.
  • Fixed "Allow only selected extensions" under Advanced Directories.
CIMCO NC-Base 7.00.20
  • Fixed bug with user is not allowed to rename files in NC-Base when "Use read-only system" is enabled.
CIMCO Software 7.00.19 PreviewReleased: 10-12-13Register to download
Changes since previous version:
CIMCO Edit 7.00.19
  • Updated Mazatrol viewer it can now show binary files without header, it determines the type from the file extension.
  • Siemens 840D (Adv): Memory consumption reduced, speed improved.
  • Fanuc: semicolon terminator in expression fixed.
  • Updated Finnish translation.
CIMCO DNC-Max 7.00.19
  • Program received by DNC is not added on import queue when it is the same.
  • Updated Finnish translation.
CIMCO MDC-Max 7.00.19
  • Fixed min/max timer values when timer goes over a period.
  • Fixed hanging of Heidenhain OCX3 protocol.
  • Fixed issue with day light savings time.
  • Fixed issue with loosing MDC configuration when running multiple instances.
CIMCO Software 7.00.18 PreviewReleased: 04-12-13Register to download
Changes since previous version:
CIMCO Edit 7.00.18
  • Fixed problem with Roaming profile.
  • Fixed GOTO statement in Siemens controller.
  • Added help file: Programming CNC-Calc Post Processor.
CIMCO DNC-Max 7.00.18
  • Updated DNC-Max help files.
  • Fixed problem with help in DNC-Max Service Manager.
CIMCO Software 7.00.17 PreviewReleased: 02-12-13Register to download
Changes since previous version:
CIMCO Edit 7.00.17
  • Updated Portuguese translation.
CIMCO DNC-Max 7.00.17
  • Updated Portuguese translation.
  • Fixed problem with configuring "Fagor 8010/8020/8025/8030" and "Farley Plasma/Laser Cut".
CIMCO Software 7.00.16 PreviewReleased: 29-11-13Register to download
Changes since previous version:
CIMCO Edit 7.00.16
  • Fixed problem with Siemens control in Backplot.
CIMCO DNC-Max 7.00.16
  • Added support for restarting MOXA W5x10A and W2x50A with password.
CIMCO MDC-Max 7.00.16
  • Web Client: Make screens auto update, when the configuration changes.
  • Web Client: Fix various bugs with status boxes.
CIMCO Software 7.00.15 PreviewReleased: 26-11-13Register to download
Changes since previous version:
CIMCO Edit 7.00.15
  • Re-enabled ISO Milling and Turning by adding two new types "Old ISO Milling" and "Old ISO Turning".
CIMCO MDC-Max 7.00.15
  • Added condition for the case that the timer is stopped.
  • Added parameter that will align max time and min time to start and end of time period if timer gets over them.
  • Fixed counting min and max values in tables when timer is running over period.
CIMCO Software 7.00.14 PreviewReleased: 22-11-13Register to download
Changes since previous version:
CIMCO Edit 7.00.14
  • Updated Swedish translation.
CIMCO DNC-Max 7.00.14
  • Updated Swedish translation.
CIMCO NC-Base 7.00.14
  • When copying a program, the name of the current program is added to the program name field.
CIMCO Software 7.00.13 PreviewReleased: 20-11-13Register to download
Changes since previous version:
CIMCO Edit 7.00.13
  • Fixed problem with paused animation is resumed when the window is resized.
  • Enable the user to change the default size of the Backplot window between 10-90% default value 66%.
  • Add the following to right click menu in Editor: * Insert Macro. * Goto Next Tool Change. * Goto Previous Tool Change.
  • Updated Swedish translation.
CIMCO DNC-Max 7.00.13
  • Added feature for deleting files via FOCAS.
  • Added feature for browsing folders on Fanuc machine via FOCAS and deleting on local PC.
  • Added delete file function for FTP client protocol.
  • Fixed DNC FOCAS receiving files.
  • Added message generated by FOCAS user macro.
  • Added number of queued programs for deleting in FOCAS DNC transmission via split window.
  • Change log level from info to error when a serial transfer is cancelled due to operator inactivity.
  • Flag a missing end trigger as an error when manually receiving files.
  • Updated Swedish translation.
CIMCO MDC-Max 7.00.13
  • Added feature for adjusting of title in pie charts.
  • Fixed issue MDC loses config file when it runs in multiple instance.
  • Added feature to use Fanuc Macro via FOCAS for MDC.
  • Improved GetdayStart function, now takes 2 param, 2dn is DayLight saving time param, default value is -1=automatic.
  • Fixed problem with wrong date in MDC command line.
  • Fixed problem with overlapped bars in MDC graph in stretch mode.
CIMCO NC-Base 7.00.13
  • Added function for ignoring files that are placed on the import queue when files are identical like a files in DB.
CIMCO Software 7.00.12 PreviewReleased: 13-11-13Register to download
Changes since previous version:
CIMCO Edit 7.00.12
  • Solid simulation: A one-time check of the PC's graphics capability is performed at start up, "Solid Animation (New OpenGL)" is only enabled if the supported OpenGL version is: >= 3.3 and Graphics card is: NVidia: GeForce, Quadro, NVS or ATI: Radeon, FirePro. All other graphics cards will by default use "Solid Animation" which supports OpenGL version >= 1.1
  • Solid simulation: Added arrows showing direction of X/Y/Z axis and added lines on the axis that appear when you click on the arrows.
CIMCO Software 7.00.11 PreviewReleased: 08-11-13Register to download
Changes since previous version:
CIMCO Edit 7.00.11
  • Added file associations in Windows Vista and newer when running as a normal user.
  • Solid simulation: Enabled rotate view for turning.
CIMCO CNC-Calc 7.00.11
  • Fixed problem with selecting post processor.
CIMCO DNC-Max 7.00.11
  • Added file associations in Windows Vista and newer when running as a normal user.
CIMCO Software 7.00.10 PreviewReleased: 06-11-13Register to download
Changes since previous version:
CIMCO Edit 7.00.10
  • Solid simulation: Helix fix (milling).
  • Solid simulation: Fix problems with file names with special chars.
CIMCO Software 7.00.09 PreviewReleased: 01-11-13
Changes since previous version:
CIMCO Edit 7.00.09
  • Fixed problem with save tool definitions and turning.
  • Solid simulation: Turning compensation fix.
  • Solid simulation: Grooving tool fix.
CIMCO CNC-Calc 7.00.09
  • The new Post Processors with NO K in their names are identical to the ones without this extension. The only difference is that the NO K's don't output the K value for G2 and G3 moves.
CIMCO Software 7.00.08 PreviewReleased: 30-10-13Register to download
Changes since previous version:
CIMCO Edit 7.00.08
  • New feature: Save tool definitions as a comment in the NC file.
  • New feature: Input fields can now be re-arranged in macros.
  • New feature: Lock of stock dimensions in milling.
  • Updated French, Italian and Polish translations.
CIMCO CNC-Calc 7.00.08
  • More variables to define the output has been moved into the globals variable section of the variables.
  • The default way to define circular movements are now set to "relative to start".
  • Older Post Processors will still work!
  • Solid simulation: Grooving tool and some bug fixes.
CIMCO DNC-Max 7.00.08
  • Updated French, Italian and Polish translations.
  • Added FTP client with split window PC|CNC.
  • Added FOCAS DNC features with split window PC|CNC.
  • Added send translator for manual send in network monitor protocol.
  • Added support in Network Protocol to send and receive files with long names to the Siemens 840D control.
CIMCO MDC-Max 7.00.08
  • Fixed issues with crashing MDC-Max client when closing windows.
  • Fixed problem with FANUC machines which do not support all FOCAS functions.
  • Optimized MDC client for faster start up in slower networks.
  • Added second title to pie charts.
  • Fixed formatting in live bar graph.
  • Added new protocol for Heidenhain Option 18 using Heidenhain DCOM object "Heidenhain OCX".
  • Added FN38 Heidenhain NCEVENT (similar to DPRINT), works only with Opt18.
  • Fixed hanging MDC client when generates a report on some computers.
  • Fixed hanging MDC rebuild of live screen on some computers.
  • Fixed issue with wrong timer values when MDC crosses over midnight.
  • Web Client: Apply modifications to make the web client work again in IE 9 and IE 10.
  • Web Client: Fix a bug that prevented Mozilla Firefox from displaying the web client.
  • Web Client: Fixed the pop-up for CSV file entry selection when the list needs to scroll.
  • Web Client: Make pop-up csv files work with both comma and semi-colon.
  • Web Client: Force IE to not use compatibility mode for intranet servers.
CIMCO Software 7.00.07 PreviewReleased: 18-10-13Register to download
Changes since previous version:
CIMCO Edit 7.00.07
  • Updated Mazatrol viewer.
  • Updated Portuguese translation.
CIMCO DNC-Max 7.00.07
  • Updated MDC-Max Web client.
  • Updated Portuguese translation.
CIMCO Software 7.00.06 PreviewReleased: 14-10-13Register to download
Changes since previous version:
CIMCO Edit 7.00.06
  • Stock Scan: Fixed problem with zero stock size in Heidenhain.
  • Added CNC-Calc Post Processor documentation to the Posts directory.
  • Made the Macro Setup window larger.
  • Solid simulation: Added cylindrical stock to Solid Animation.
  • Solid simulation: Drilling tool is supported.
  • Solid simulation: Any non-along-Z-axis movements are marked as clash (red color).
CIMCO DNC-Max 7.00.06
  • Updated MDC-Max Web client.
CIMCO Software 7.00.05 PreviewReleased: 08-10-13
Changes since previous version:
CIMCO Edit 7.00.05
  • Fixed problem with crash report when closing the editor.
  • Updated Czech translation.
  • Solid simulation: Fixed problem with regenerate solid.
  • Solid simulation: Made Solid Animation (New GL) default.
CIMCO CNC-Calc 7.00.05
  • In this version of CNC-Calc a change has been made to the post processors (backwards compatible). It is now possible to add 2 new functions in both milling and turning post processors: These functions are onOpen and onClose. These functions are called at the start of a program and at the end of the program. In order to make the Post Processors backward compatible post processors without these two functions will still work as they did before. If on the other hand they are added they will work as described below. They could look something like functions shown below: The onOpen is called with the variable isClipboard. This is a boolean variable that tells the post processor if the program is exported to the clipboard or the editor. When this value is saved in the onOpen function it is also possible to make the behaviour of the onClose function dependant on what kind of export operation that are performed. If a variable is used in the onOpen function like the exportToClipboard in the shown functions, please remember to define this as: var exportToClipboard; Outside the 2 functions to give it a global scope. In the 2 functions below a comment will be inserted at the start of the program to indicate if this is a clipboard or editor export. If it was an editor export the last line in the NC Program will be a M30 but if it was a clipboard export this line will be omitted. function onOpen(isClipboard){ exportToClipboard = isClipboard; if (exportToClipboard) { onComment("Exporting to Clipboard"); } else { onComment("Exporting to Editor"); } } function onClose(){ if (!exportToClipboard) { writeBlock("M30"); } }
CIMCO DNC-Max 7.00.05
  • Updated MDC-Max Web client.
  • Updated Czech translation.
CIMCO Software 7.00.04 PreviewReleased: 03-10-13
Changes since previous version:
CIMCO Edit 7.00.04
  • Updated help files.
CIMCO CNC-Calc 7.00.04
  • Before the Post Processor is called CNC-Calc will now verify that the Post Processor exists. If this is not the case a warning will be shown and the user is asked to select a new Post Processor.
  • Solid simulation: 3D Milling and Turning: Added color coding of tools.
  • Solid simulation: 2D Turning: Added color coding of tools.
CIMCO DNC-Max 7.00.04
  • Updated MDC-Max Web client.
CIMCO Software 7.00.03 PreviewReleased: 25-09-13Register to download
Changes since previous version:
CIMCO Edit 7.00.03
  • Solid simulation: (New GL) improved performance, added support for recent Intel graphics cards: Intel HD Graphics 4000 and later.
  • Solid simulation: Added cross section in turning.
  • Solid simulation: DNC-Max / MDC-Max Update.
CIMCO DNC-Max 7.00.03
  • Minor fixes to Web client configuration.
CIMCO Software 7.00.02 PreviewReleased: 24-09-13Register to download
Changes since previous version:
CIMCO Edit 7.00.02
  • Updated French translation.
CIMCO DNC-Max 7.00.02
  • Updated French translation.
  • Added DNC-Max Web client, it allows users with a Web browser / Tablet / Smart phone to control the machines.
  • Added MDC-Max Web client, it allows users with a Web browser / Tablet / Smart phone to access operator screens.
CIMCO Software 7.00.01 PreviewReleased: 20-09-13Register to download
Changes since previous version:
CIMCO Edit 7.00.01
  • Updated Fanuc control.
CIMCO Software 7.00.00 PreviewReleased: 16-09-13
Changes since previous version:
CIMCO Edit 7.00.00
  • New feature: Post Processor in MiniCAD.
  • New feature: Solid Animation of both Milling and Turning in Backplot.
  • New feature: 2D turning in Backplot.
  • New feature: Scanning of tool information from comment in NC file.
  • New feature: Scanning of block size from comment in NC file. CIMCO Edit V6 History NOTICE: Valid maintenance is required to install this download!