Advanced

This section describes the setup and use of the NC-Base Server's Advanced features.

To open the Advanced dialog, select Setup in the Administration menu, or click the Setup dialog launch icon in the Database menu. This will open the CIMCO NC-Base Configuration window. Click on Server Settings in the left hand list and select Advanced. The following dialog appears:

Advanced Server Settings.

Server Settings

param

Use versioning system

Check this field to enable the versioning system. When the versioning system in enabled, NC-Base will automatically create a backup when updating a file. The Maximum number of backups setting controls how many old versions should be retained. If you have one or more machines that use large 3D files, you can disable the versioning system for these machines in the machine setup. When using versioning, it will take a little longer to open and/or close a file because NC-Base needs to create a backup file.

param

Use read-only system

Check this field to enable the read-only system. When this system is enabled, users cannot edit files marked as read-only.

param

Set program info read-only

Check this field if program info should be read-only when the program is set to read-only.

param

Use locking system

Check this field to enable the locking system. When this system is enabled, users are only allowed to send unlocked programs.

param

Set unlocked files read-only

Check this field if all unlocked files should be marked as read-only. This prevents unauthorized changes to unlocked files.

param

Set read-only attr. on program files

Check this field if the read-only file system attribute should be set on program files, when the program is marked as read-only.

When the read-only attribute is set, external programs cannot modify/delete the file.

param

Set read-only attr. on associated files

Check this field if the read-only file system attribute should be set on associated files, when the program is marked as read-only.

When the read-only attribute is set, external programs cannot modify/delete the file.

param

Backup files when setting read/write

Check this field if program files should be backed up when a program is changed from read-only to read/write.

param

Backup associated when setting read/write

Check this field if associated files should be backed up when a program is changed from read-only to read/write.

param

Only backup if changed

Check this field if backups should only be generated, if the file is different from the latest backup.

param

Backup before restoring

Check this field if a backup should be created before restoring a file.

param

Backup programs before editing

Check this field to automatically backup program files before editing them.

param

Backup associated files before editing

Check this field to automatically backup associated files before editing them.

param

Check backups using file time

Check this field if NC-Base should only use the time stamp of a file to check if it is changed.

The time stamp might fail to identify changed files on some network drives and operating systems. If NC-Base does not generate backups correctly, remove the check from this field.

param

Use CIMCO DNC-Max

Check this field if CIMCO DNC-Max should be used as DNC link.

param

Enable NC-Base Secure Mode

Check this field to enable the secure mode. When NC-Base is running in secure mode, users do not need write access to the NC-Base base directory.

param

Disable user management

Check this field to disable user management.

param

List all users on login dialogs

Check this field if the login dialog should show a list of all users.

param

Hide timestamps on ribbon bar

Check this field to hide the file created/modified time shown on the ribbon bar above the preview window.

param

Restrict groups to specific computers

Check this field if individual user groups should be restricted to specific computers.

When this field is selected, the User group setup will have a check box next to each group. Check these to specify which groups can login to NC-Base from this computer.

param

Allow users to change password

Check this field to allow users to change their passwords.

param

Keep extension in program name

Check this field to keep the file extension as part of the program name.

param

Update program info when editing files

Check this field to update the database information when editing the NC file.

You must configure the Program Format Triggers to use this option.

param

Update files when updating program info

Check this field to update the database information specified in the NC file when updating the database info.

You must configure the Program Format Triggers to use this option.

param

Allow 'Restore All'

Check this field to allow user to restore programs and associated files from the Restore dialog.

When this option is selected, a backup is created for associated files even if they are not changed since the last backup.

param

New Setup/Tool/Memo file on copy

Check this field if a new Memo/Setup/Tool file should be created when a program is copied.

If this option is not selected, the user will be prompted if the file should be copied. When the file is not copied, a link to the existing file is created.

param

Do not copy associated files on copy

Check this field if associated files should not be copied/linked to the new program when copying an existing program.

param

Use 'Family of parts'

Check this field to allow specifying multiple part numbers for one program.

param

Backup/restore program information

Check this field to restore the program fields when restoring a program.

param

Do not allow sending files on the import queue

Check this field if operators are not allowed to send files waiting on the import queue.

Remote request is normally not possible unless the DNC-Max port is configured to look for files on the import queue.

param

Primary data is not NC data

Check this field to change NC-Base mode. When checked, NC-Base assumes that the primary program file is not an NC program but a CAM file or similar.

param

Revision all saves

Check this field to revise all saves from the editor. If this option is not checked, the file is only revised the first time it is saved, and will not be revised again until the file is closed and opened again.

param

Lock programs when restoring

Check this field to lock programs when restoring the program file from a backup.

param

Unlock new programs

Check this field to set new programs unlocked when added by a user that does not have permission to unlock programs.

param

Do not prompt to set programs read/write in editor

Check this field to disable the Set program read/write message when editing read-only programs.

param

Use 'Transfer Limit Counter'

Check this field to use the Transfer Limit Counter option.

When this option is enabled, the number of times a file can be transferred is specified on the program info dialog. When this counter reaches 0, the program can no longer be transferred.

param

Use 'Transfer Limit Timer'

Check this field to use the Transfer Limit Timer option.

When this option is enabled, a file can only be transferred until the transfer time expires. When the timer reaches 0, the program can no longer be transferred.

param

Use 'Transfer Limit Window'

Check this field to use the Transfer Limit Window option.

When this option is enabled, a timer is started when a file is transferred. When the timer reaches 0, the program can no longer be transferred.

param

Set Transfer Limit when restoring

Check this field if the Transfer Count Limit should be set to the default value (specified under Server Settings, Other) when restoring a program.

param

Set transfer limit per machine

Check this field to set individual default transfer limits for each machine.