CIMCO Software 6 Releases
Release notesExpand allCollapse all
Changes since previous version:
CIMCO DNC-Max 6.30.07
- Added option to created dummy file (with the same name like is folder) to keep NCBase data structure when a folder is processed (i.e.: Siemens WPD folder)
- Added option to rename associated file (like in auto receive), associated file has same name as main file.
- added delay before process associated files (because of delay in network when more files are copied into auto import folder). Auto Receive:
- Added option to create dummy file to keep NCBase data structure when a folder is processed (i.e.: Siemens WPD folder).
- Added multiple folders receive. DNC server can process more than only one folder during auto-receive operation.
- Added option rename files according to "dhinf.000" on Siemens machines.
- Changed option to setup loop period from integer to float, is possible to define shorter time then 1 minute with keeping backward compatibility (faster scanning of monitored folders).
- Added feature that all associated files are processed after all can be opened for writing. (It means after all files are successfully copied in final destination).
CIMCO NC-Base 6.30.07
- Fixed issue in NCBase when the main program has lot of associated files (i.e. 300 assoc. files)
- Updated version system in NCBase for programs received by DNC server
Changes since previous version:
CIMCO DNC-Max 6.30.06
- Fixed "Allow only selected extensions" under Advanced Directories.
CIMCO NC-Base 6.30.06
- Fixed bug with user is not allowed to rename files in NC-Base when "Use read-only system" is enabled.
Changes since previous version:
CIMCO DNC-Max 6.30.05
- Program received by DNC is not added on import queue when it is the same.
CIMCO MDC-Max 6.30.05
- Fixed min/max timer values when timer goes over a period.
- Fixed hanging of Heidenhain OCX3 protocol.
- Fixed issue with day light savings time.
- Fixed issue with loosing MDC configuration when running multiple instances.
Changes since previous version:
CIMCO DNC-Max 6.30.04
- Fixed crashing DNC client when Receive button is pushed and port is not an FTP client.
CIMCO MDC-Max 6.30.04
- Fixed hanging MDC client when generates a report on some computers.
- Fixed hanging MDC rebuild of live screen on some computers.
- Fixed issue with wrong timer values when MDC crosses over midnight.
Changes since previous version:
CIMCO DNC-Max 6.30.03
- Added FTP client with split window PC|CNC.
- Added FOCAS DNC features with split window PC|CNC.
- Added send translator for manual send in network monitor protocol.
- Added support in Network Protocol to send and receive files with long names to the Siemens 840D control.
CIMCO MDC-Max 6.30.03
- Fixed issues with crashing MDC-Max client when closing windows.
- Fixed problem with FANUC machines which do not support all FOCAS functions.
- Optimized MDC client for faster start up in slower networks.
- Added second title to pie charts.
- Fixed formatting in live bar graph.
- Added new protocol for Heidenhain Option 18 using Heidenhain DCOM object "Heidenhain OCX".
- Added FN38 Heidenhain NCEVENT (similar to DPRINT), works only with Opt18.
Changes since previous version:
CIMCO DNC-Max 6.30.02
- Fixed issue with uploading files in secure mode in some windows version.
- Added receive and send translators in the network protocol.
CIMCO MDC-Max 6.30.02
- Fixed MDC Max Client from command line.
- Fixed issue in MDC engine with too long formula.
Changes since previous version:
CIMCO DNC-Max 6.30.01
- Added bidirectional program transfer option for FTP client protocol.
- Standardization of the network protocols.
- Fixed memory issue in the MTConnect protocol.
Changes since previous version:
CIMCO DNC-Max 6.20.39
- Fix Mazak Smart FTP reset problem.
- Improved option in Network Protocol to send detailed success and error reports back to the operator (Same reports as the serial protocol).
CIMCO MDC-Max 6.20.39
- Added support for calculating with floating piont numbers.
- Added support for CSV files along with Excel (Excel variables 1-4).
- Fixed issue with DB fields not matching.
Changes since previous version:
CIMCO Edit 6.20.38
- Updated Finnish and Swedish translation.
CIMCO DNC-Max 6.20.38
- Updated Finnish and Swedish translation.
- Support of the MTConnect protocol.
CIMCO NC-Base 6.20.38
- Fixed issue with check box user account.
- Fixed problem with resource of dialog for login information.
Changes since previous version:
CIMCO Edit 6.20.37
- Updated French and Hungarian translation.
CIMCO DNC-Max 6.20.37
- Updated French and Hungarian translation.
- Fixed problem with alarm messages in Heidenhain Option 18 protocol.
CIMCO MDC-Max 6.20.37
- Fixed output directory for HTML reports.
Changes since previous version:
CIMCO Edit 6.20.36
- Updated Danish translation.
- Updated Czech help file for the Editor.
- Fixed problem with missing icons.
CIMCO DNC-Max 6.20.36
- Added support for Heidenhain Option 18 protocol.
CIMCO MDC-Max 6.20.36
- Fixed XML Export with empty values.
Changes since previous version:
CIMCO Edit 6.20.35
- Fixed problem with cylindrical stock in Backplot.
Changes since previous version:
CIMCO CNC-Calc 6.20.34
- Fixed error that causes CNC-Calc to crash when DNC-Max Client is open.
- The correct Machine Zero window is now loaded depending on file type.
CIMCO DNC-Max 6.20.34
- Added support for SSL/TLS when sending emails.
CIMCO MDC-Max 6.20.34
- Fixed problems with special chars in filenames when exporting to XML.
Changes since previous version:
CIMCO Edit 6.20.33
- Updated Mazatrol viewer.
- Updated French and Swedish translation.
CIMCO DNC-Max 6.20.33
- Updated French and Swedish translation.
CIMCO MDC-Max 6.20.33
- Added option for MDC-Max to export reports from the command line.
CIMCO Software 6.20.32 Released: 21-05-13
Changes since previous version:
CIMCO Edit 6.20.32
- Added Load/Save of toolchains.
- Added basic scanning of tool information from comment in NC file.
- Added scanning of block size from comment in NC file.
- Updated Mazatrol viewer.
- Fixed viewing of help files.
- Updated Spanish, French, Czech language file.
CIMCO DNC-Max 6.20.32
- Updated Spanish, French, Czech language file.
CIMCO Software 6.20.31 Released: 15-04-13
Changes since previous version:
CIMCO Edit 6.20.31
- Updated Spanish language file.
- Fixed problems in NC Functions.
CIMCO DNC-Max 6.20.31
- Added option to disable send translators in "Send File Advanced"
- Added option in Directory Protocol / Network Protocol to send a error report back to the operator.
- Added option in Directory Protocol / Network Protocol to send a success report back to the operator.
CIMCO MDC-Max 6.20.31
- Fix invalid filenames (with slashes) when exporting XML files.
CIMCO NC-Base 6.20.31
- NCBase DB configuration "Default" was changed to "Cancel" button.
CIMCO Software 6.20.30 Released: 20-03-13
Changes since previous version:
CIMCO Edit 6.20.30
- Updated Spanish and Portuguese language files.
CIMCO DNC-Max 6.20.30
- Added support for FTP Server to remember last opened directory for X seconds.
- Added support for remote request with barcode reader, on mazatrol port.
CIMCO MDC-Max 6.20.30
- Added option to move last shift 1 day.
- Added option to export reports as XML.
- Added support for stretching bars (columns) in MDC graphs.
- Added support for rotating of tags in graphs.
- Added support for autosize of tag font.
- Added support customizing of tags in graphs and also in reports.
CIMCO NC-Base 6.20.30
- Added option to rename an associated file.
CIMCO Software 6.20.29 Released: 30-01-13
Changes since previous version:
CIMCO DNC-Max 6.20.29
- added suport for NC Base events, linked into DNC OEM interface.
CIMCO MDC-Max 6.20.29
- fixed problem with sending MDC notification during break and out of shift.
CIMCO Software 6.20.28 Released: 25-01-13
Changes since previous version:
CIMCO Edit 6.20.28
- Add Haas Milling and Haas Turning to default machine list.
- Updated Editor help for CZ, DE, FR, SP, US.
- Updated Czech language file.
CIMCO DNC-Max 6.20.28
- Added new function IsFileLocked, this function is called when a program in NCBase is locked/unlocked.
CIMCO MDC-Max 6.20.28
- Added new MDC function for number tags in graphs.
CIMCO Software 6.20.27 Released: 16-01-13
Changes since previous version:
CIMCO Edit 6.20.27
- Updated Mazatrol viewer.
- Added multiline search and replace.
- Added support for 4-Axis milling to Backplot
- Fixed problem with Remove String
CIMCO DNC-Max 6.20.27
- Directory monitor template, fixed error message on locked files.
- Messaging CTS/DSR Monitor, fixed the "Push button" input type.
CIMCO MDC-Max 6.20.27
- Added new feature in MDC client: The number displayed at each column in graphs matches with the number in the legend.
- Fixed Seconds format.
CIMCO Software 6.20.26 Released: 11-12-12
Changes since previous version:
CIMCO DNC-Max 6.20.26
- Fix for Ticket #15 NC-Base wrong "To:" field.
Changes since previous version:
CIMCO DNC-Max 6.20.25
- Added lock/unlock file message to monitor log.
CIMCO Software 6.20.24 Released: 07-12-12
Changes since previous version:
CIMCO CNC-Calc 6.20.24
- The Chamfer Distance Angle has been corrected.
CIMCO DNC-Max 6.20.24
- Added the option to disable Transmit Translators on Remote Requests
CIMCO MDC-Max 6.20.24
- Fix for Ticket #9 MDC e-mails with wrong headers.
CIMCO Software 6.20.23 Released: 30-11-12
Changes since previous version:
CIMCO MDC-Max 6.20.23
- Fixed problem with week numbers
Changes since previous version:
CIMCO Edit 6.20.22
- Updated Mazatrol viewer.
Changes since previous version:
CIMCO MDC-Max 6.20.21
- Fixed problem generating reports when using MS SQL in some cases.
Changes since previous version:
CIMCO Edit 6.20.20
- Updated Mazatrol viewer.
Changes since previous version:
CIMCO DNC-Max 6.20.19
- Added option to use program with the highest number as the main program file in the directory monitor protocol. Ref: Setup/Port/Configure Port/Auto Receive/Set/ Associated Files/Main program has highest number
Changes since previous version:
CIMCO DNC-Max 6.20.18
- Fixed problem collecting alarms over Fanuc Focas for some control types.
Changes since previous version:
CIMCO Edit 6.20.17
- Updated CNC-Calc.
- Updated Mazatrol viewer.
CIMCO MDC-Max 6.20.17
- Fixed problem rebuilding MDC data in some cases.
CIMCO NC-Base 6.20.17
- Fixed problem re-connection to MS SQL in some cases.
Changes since previous version:
CIMCO DNC-Max 6.20.16
- Added option to control expansion of Database variable when sending programs.
Changes since previous version:
CIMCO Edit 6.20.15
- Updated Mazatrol viewer.
Changes since previous version:
CIMCO NC-Base 6.20.14
- Fixed problem using field folders in some cases.
Changes since previous version:
CIMCO Edit 6.20.13
- Updated Mazatrol viewer.
CIMCO NC-Base 6.20.13
- Fixed problem with two message CSV files being generated when deleting a program with the CSV feature enabled.
- Added message CSV file when pruging a program with the CSV feature enabled.
Changes since previous version:
CIMCO DNC-Max 6.20.12
- Fixed problem using Focas monitoring.
CIMCO Software 6.20.11 Released: 12-09-12
Changes since previous version:
CIMCO DNC-Max 6.20.11
- Fixed problem sending files using Fanuc FOCAS.
Changes since previous version:
CIMCO Edit 6.20.10
- Updated Mazatrol viewer.
CIMCO DNC-Max 6.20.10
- Added option in the directory monitor protocol to send files using Fanuc FOCAS. Setup/Configure Port/Advanced/Other/Send file using Fanuc FOCAS
CIMCO NC-Base 6.20.10
- Fixed problem using predefined fields when 'Family of parts' was enabled.
- Fixed problem increasing versions when 'No version until approved/checked' was selected when status system was disabled.
Changes since previous version:
CIMCO NC-Base 6.20.09
- Fixed file save error when using NC-Base secure mode. (Introduced in 6.20.08)
Changes since previous version:
CIMCO NC-Base 6.20.08
- Fixed problem with user password being reset after modifying user info.
- Fixed problem with version being incremented in some cases when opening files from a network drive that was unavailable.
Changes since previous version:
CIMCO NC-Base 6.20.07
- Fixed problem with incorrect field folders when field names were 'long'.
Changes since previous version:
CIMCO MDC-Max 6.20.06
- Fixed problem with incorrect MDC event or no MDC event was send.
Changes since previous version:
CIMCO Edit 6.20.05
- Changed simple math functions to keep a 0 when result would have been empty or just a decimal character.
- Fixed problem with "Strip leading 0's" and "Keep decimals" not remebered on the simple math function dialog.
CIMCO DNC-Max 6.20.05
- Added dialog showing when server backup was successfully saved.
- Fixed problem with the message setting 'Extract value/Next line if received within...'.
- Fixed problem selecting MDC/Message "many" events for a single e-mail/SMS recipient.
CIMCO MDC-Max 6.20.05
- Changes setup to not allow creating messages and events with the same name.
- Fixed problem selecting black as color on table/graphs/timelines
- Fixed problem setting TEXT[EXCELVAR2] - TEXT[EXCELVAR4]
- Fixed problem with MDC SMS/E-mail notifications not always being send.
CIMCO NC-Base 6.20.05
- Fixed problem deleting associated files.
Changes since previous version:
CIMCO Edit 6.20.04
- Added support for specifying any prefix string in the math functions 'Other' field.
- Updated Mazatrol viewer.
CIMCO MDC-Max 6.20.04
- Added support for using TEXT[PORTNAME], TEXT[DNCGROUP], TEXT[MDCGROUP] and TEXT[NCBASEGROUP]in table columns.
- Added translation for 'NONE' for the operator, program and job.
- Fixed problem with first message after start/configuration change did not trigger an update.
- Fixed incorrect/double updates of event log. (Introduced i 6.20.02).
- Fixed live screen / operator screen hang.
CIMCO NC-Base 6.20.04
- Added computer name to the NC-Base backup filename.
- Increased the maximum number of files on the transfer queue from 128 to 1024.
- Fixed problem sending multiple files from the NC-Base client in some cases.
- Fixed problem deleting program when server did not have permission to delete file and secure mode was enabled.
Changes since previous version:
CIMCO Edit 6.20.03
- Added support for using the math functions with values like X=, X: and X:=
- Swapped the menu buttons for 'DNC-Max Server Restart' and 'DNC-Max Server Configure' when using the editors DNC-Max Client.
- Fixed problem copying changed settings when adding a new machine type.
CIMCO DNC-Max 6.20.03
- Updated DNC-Max client to show the IP address of FTP server/clients machines in the port list.
- Increased size of server configuration dialogs.
- Added additional debug information to the smtp debug log.
CIMCO MDC-Max 6.20.03
- Added support for using variables in table columns.
- Added option to edit the event log. Ref: Setup/System Setup/Messages/Allow editing the event log
- Added standard messages (PORTONLINE, PORTOFFLINE, ...) to the event log message filter.
- Increased maximum number of timers to 96.
- Fixed problem where only first page of compact tables where printed.
- Fixed problem updating Excel variable setup.
- Fixed problem showing 'All' events in the event log.
- Fixed problem with timer events being send twice when a clear condition was specified.
CIMCO NC-Base 6.20.03
- Added option to associate auto import files with the program in the same directory Ref: Setup/Configure Server/NC-Base/Auto Import Associate files with program in the same directory
- Fixed \\ in autoimported file names in some cases. (introduced in 6.20.01)
- Fixed problem rejecting a single associated file.
- Fixed problem modifying name/machine on programs associated with machines where field folders were disabled.
Changes since previous version:
CIMCO Edit 6.20.02
- Fixed licensing problem when showing some Mazatrol files.
CIMCO DNC-Max 6.20.02
- Added support for redirecting remote requests when using barcode redirect.
- Added support for controling RTS / DTR outputs using MDC-Max. Ref: Setup/Port/Configure Port/Messaging/CTS Monitor/RTS Output Signal Ref: Setup/Port/Configure Port/Messaging/DSR Monitor/DTR Output Signal
CIMCO MDC-Max 6.20.02
- Fixed problem configuring MDC-Max events / crash when opening the MDC-Max configuration. (Introduced in 6.20.01).
Changes since previous version:
CIMCO DNC-Max 6.20.01
- Added option to send files associated in NC-Base when remote requesting a file in the standard protocol. Ref: Setup/Port/Configure Port/Remote Request/Set/Multi Request/ Associated files
- Fixed delays when using the debug log on some systems.
CIMCO MDC-Max 6.20.01
- Added option to use machine variables 1-4 as the machine name on the operator screen machine list. Ref: Setup/System Setup/Operator Screens/Machine name in list
- Added support for using TEXT[MCHVAR1] - TEXT[MCHVAR4].
- Fixed spacing problems when using math operators in state titles.
CIMCO NC-Base 6.20.01
- Added option to control where sub-programs/associated files are stored. Ref: Database/Setup/Server Settings/Associated Files/ Memo file directory mode Ref: Database/Setup/Server Settings/Associated Files/ Tool list directory mode Ref: Database/Setup/Server Settings/Associated Files/ Setup sheet directory mode Ref: Database/Setup/Server Settings/Associated Files/ Other files directory mode Ref: Database/Setup/Server Settings/Associated Files/ Sub-program directory mode
- Added additional warning messages when program rename/move conflicts with an existing program.
- Changed sub-programs to default to the program file directory.
- Fixed problem when auto importing deleted files/programs.
- Fixed problem with auto impor not ignoring identical files when program was locked or deleted, and the option to set locked or deleted files offline was enabled.
- Fixed problem using the auto import 'Keep Directory' option together with Customer / Field folders.
- Fixed problem locking a program when using 'Copy Program'.
Changes since previous version:
CIMCO MDC-Max 6.10.60
- Fixed problem with screens/repors showing delete programs when other program with the same name existed.
CIMCO NC-Base 6.10.60
- Fixed problem viewing/comparing with files on the import queue when the 'Add associated files to the import queue' option is enabled.
Changes since previous version:
CIMCO NC-Base 6.10.59
- Fixed problem exporting program list in some cases.
Changes since previous version:
CIMCO NC-Base 6.10.58
- Fixed problem exporting program list in some cases.
Changes since previous version:
CIMCO MDC-Max 6.10.57
- Fixed problem opening the MDC configuration on some systems when using MS SQL.
Changes since previous version:
CIMCO DNC-Max 6.10.56
- Changed barcode readers to log PORTONLINE/PORTOFFLINE message for the port they are attached to.
Changes since previous version:
CIMCO DNC-Max 6.10.55
- Added support for creating backups when receiving files over LVS-2 TCP/IP.
- Fixed problem showing file listing in the split window when sending files over LSV-2 TCP/IP.
- Fixed 'File Overwrite' warning when copying files to the PC using the LSV-2 split window function.
Changes since previous version:
CIMCO DNC-Max 6.10.54
- Fixed crash when remote reqested program not found in the Mazatrol protocol.
Changes since previous version:
CIMCO MDC-Max 6.10.53
- Added option to specify the font size for the title text on live screens. Ref: Setup/System Setup/Status Screens/Main Bar title font size
CIMCO NC-Base 6.10.53
- Fixed crash when selecting programs with more than >200 associated files using MS SQL.
Changes since previous version:
CIMCO DNC-Max 6.10.52
- Fixed problem auto receiving some files in the directory monitor protocol.
CIMCO MDC-Max 6.10.52
- Fixed font scaling problem on operator screen buttons.
CIMCO Software 6.10.51 Released: 20-04-12
Changes since previous version:
CIMCO Edit 6.10.51
- Fixed problem using /lang=XX with some other command line options.
Changes since previous version:
CIMCO MDC-Max 6.10.50
- Added option to sort license screens by field. Ref: Setup/System Setup/Live Screens/Sort by field
CIMCO NC-Base 6.10.50
- Added option to set program info read-only when program is read-only. Ref: Database/Setup/Server Settings/Set program info readonly
Changes since previous version:
CIMCO DNC-Max 6.10.49
- Added support for sending files to Heidenhain controls using LSV2 TCP. Ref: Setup/Port/Configure Port/Advanced/Other/ Heidenhain TNC LSV-2 over TCP/IP
Changes since previous version:
CIMCO Edit 6.10.48
- Updated Mazatrol viewer.
CIMCO DNC-Max 6.10.48
- Added option to process files using normal auto receive are splitting the files using the WPD split option. Ref: Setup/Port/Configure Port/Auto Receive/Set/ Auto receive after splitting (ignores program name)
- Fixed crash when rebuilding MDC monitoring data with large gaps in dates with data.
- Fixed problem with some SMS modems.
CIMCO NC-Base 6.10.48
- Added option to set associated files offline when deleting programs. Ref: Database/Setup/Server Settings/Set associated files offline
- Rejected files are now moved to the "System\Deleted" folder.
Changes since previous version:
CIMCO DNC-Max 6.10.47
- Fixed problem with auto receive/remote request not working in the directory monitor. (Introduced in 6.10.45).
CIMCO NC-Base 6.10.47
- Fixed problem with incorrect files being rejected from the queue. (Introduced in 6.10.35 - Critical bug).
- Fixed problem showing associated files on the import queue when multiple programs is on the queue.
Changes since previous version:
CIMCO DNC-Max 6.10.46
- Fixed problem with 'Wait for XOn' when 'Strip control characters' was enabled.
CIMCO NC-Base 6.10.46
- Changed purge to perform a reject when searching the import queue.
Changes since previous version:
CIMCO Edit 6.10.45
- Added button to send selected lines.
- Updated Mazatrol viewer.
- Updated backplot.
- Fixed problem with overlapping characters when using ClearType(tm).
CIMCO DNC-Max 6.10.45
- Added option to strip control characters from DPRNT/barcode messages. Ref: Setup/Port/Configure Port/Messaging/DPRNT / Barcodes/ Strip control characters
- Added support for remote requesting files in the directory monitor protocol using a barcode port.
- Added support for auto receiving associated files to the import queue in the directory monitor protocol.
Changes since previous version:
CIMCO DNC-Max 6.10.44
- Fixed crash when using I/O modules. (Introduced in 6.10.37).
Changes since previous version:
CIMCO MDC-Max 6.10.43
- Fixed problem using TEXT[DATAVAR6], TEXT[DATAVAR6] and TEXT[DATAVAR8]
Changes since previous version:
CIMCO Edit 6.10.42
- Fixed problem when using Mazak M950 - M997 synchonization commands in multi channel view.
CIMCO DNC-Max 6.10.42
- Fixed problem inserting MDC message variables in MSGTEXT 1-16. (Introduced in 6.10.37).
Changes since previous version:
CIMCO Edit 6.10.41
- Added Mazak multi channel view configurations.
CIMCO DNC-Max 6.10.41
- Added NC-Base log message when receiving unchanged associated files in the directory monitor protocol.
Changes since previous version:
CIMCO DNC-Max 6.10.40
- Added option to return success when deleting a file in the FTP server protocol and file deletion is disabled.
- Fixed problem when auto importing files into NC-Base using the directory monitor protocol and the 'Use directopry name as program name' option was selected.
Changes since previous version:
CIMCO Edit 6.10.39
- Updated Mazatrol viewer.
CIMCO DNC-Max 6.10.39
- Improved resolution of pin monitor timeouts.
CIMCO NC-Base 6.10.39
- Fixed problem using log view compare button on sub-programs and associated files.
- Fixed problem using log view restore button on sub-programs and associated files.
- Fixed problem increasing file version when receiving a file identical to the previous backup.
Changes since previous version:
CIMCO DNC-Max 6.10.38
- Fixed problem using the Interval option when summarizing events/messages.
Changes since previous version:
CIMCO MDC-Max 6.10.37
- Added options to summarize events from monitoring devices that generates messages at a high frequency. Ref: Setup/Configure Server/Events / Messages/Sum Ref: Setup/Configure Server/Events / Messages/Timeout Ref: Setup/Configure Server/Events / Messages/Interval
- Fixed double spaces in some text strings on live screens and MDC telnet connections.
- Fixed problems using default Excel values when a unit was specified.
Changes since previous version:
CIMCO DNC-Max 6.10.36
- Fixed problem auto receiving some files in the directory monitor protocol.
CIMCO MDC-Max 6.10.36
- Added support for specifying units for Excel variables. Ref: Setup/System Setup/Excel Variables/Unit
- Increased total number of states from 500 to 1000.
CIMCO NC-Base 6.10.36
- Fixed crash when selecting programs with more than >200 associated files.
Changes since previous version:
CIMCO Edit 6.10.35
- Updated Mazatrol viewer.
CIMCO DNC-Max 6.10.35
- Fixed problem redirecting MDC messages to Directory Monitor protocol ports.
- Fixed problem inserting filenames longer than 16 characters in Mazatrol program when using the "Insert filename in comment".
CIMCO NC-Base 6.10.35
- Changed autoimport to skip associated files when program is read-only and "Do not overwrite Read-Only programs" is selected.
- Fixed problem rejecting sub-programs when rejecting main program.
Changes since previous version:
CIMCO Edit 6.10.34
- Updated Mazatrol viewer.
CIMCO DNC-Max 6.10.34
- Added support for using database variables in translators. Variables supported: $DBPROGRAM, $DBPRGFIELD1, $DBPRGFIELD2, $DBPRGFIELD3, $DBPRGFIELD4, $DBPRGFIELD5, $DBPRGFIELD6, $DBPRGFIELD7, $DBPRGFIELD8, $DBPRGFIELD9, $DBPRGFIELD10, $DBPRGTXLIMIT, $DBDELETEDBY, $DBCREATEDBY, $DBMODIFIEDBY, $DBUNLOCKEDBY, $DBREADONLYBY, $DBUNREADONLY, $DBPROJECT, $DBCREATED, $DBMODIFIED, $DBDELETED, $DBREADONLY, $DBUNLOCKED, $DBSTATUS, $DBFILE, $DBFILESHORT, $DBFILEDIR, $DBFILEDESCRIPTION, $DBFILEDELETEDBY, $DBMACHINEGROUP, $DBCUSTOMER, $DBADDRESS, $DBADDRESS2, $DBCITY, $DBCOUNTRY, $DBTELEPHONE, $DBZIPCODE, $DBFAX, $DBHOMEPAGE, $DBCUSTOMERSTATE, $DBUSER
CIMCO NC-Base 6.10.34
- Changed import queue to ignore un-changed program files.
- Fixed problem showing associated files on the import queue when searching the queue.
Changes since previous version:
CIMCO MDC-Max 6.10.33
- Fixed problem showing/updating live screen in some cases.
Changes since previous version:
CIMCO Edit 6.10.32
- Fixed problem setting the file changed falg after closing a multi channel view.
CIMCO DNC-Max 6.10.32
- Added support for aborting current transfer when using request redirect and 'Abort if new transfer' is enabled.
CIMCO NC-Base 6.10.32
- Added support for extracting info from older Griffo binary headers.
- Fixed problem extracting info from Griffo binary headers.
Changes since previous version:
CIMCO CNC-Calc 6.10.31
- Turning Roughing and Finish improved so there is now both axial and radial plunge.
CIMCO DNC-Max 6.10.31
- Fixed problem auto receiving files after using a compare runner.
CIMCO MDC-Max 6.10.31
- Fixed problem specifying messages for input fields if an undefined message was used.
CIMCO NC-Base 6.10.31
- Added support for exporting the program status when exporting program lists.
- Fixed problem specifying name of program lists exported to excel.
Changes since previous version:
CIMCO Edit 6.10.30
- Updated Mazatrol viewer.
CIMCO DNC-Max 6.10.30
- Changed directory monitor protocol to update existing program in NC-Base whwn auto receiving using directory name as program name and a program existed in the same directory.
- Fixed problem send files over FTP containing only one program when using the split file option.
Changes since previous version:
CIMCO DNC-Max 6.10.29
- Added option to use 'Wait for data' after sending start of feed data. Ref: Setup/Port/Configure Port/Transmit/ Wait after sending 'Start of feed' data
- Fixed problem with differences listed in compare reports for non-existing files.
- Fixed problem with file being locked after using the FTP send split file option.
CIMCO NC-Base 6.10.29
- Fixed permission issue when adding programs using Drag'N'Drop.
Changes since previous version:
CIMCO Edit 6.10.28
- Updated Mazatrol viewer.
- Updated Heidenhain macros.
CIMCO DNC-Max 6.10.28
- Fixed problem specifying -1 as minimum cycle time to allow very short pulses when using Moxa E12xx I/O devices.
CIMCO MDC-Max 6.10.28
- Fixed incorrect sum/average on event log tables.
- Fixed problem showing live screens in full screen mode on secondary monitor on some systems.
- Fixed problem with $xxxSHIFTSTART and $xxxSHIFTEND variables.
CIMCO NC-Base 6.10.28
- Fixed problem changing program group when associated NC data was located in main directory and a 'Other' directory was specified.
- Fixed permission issue when adding programs using Drag'N'Drop.
Changes since previous version:
CIMCO Edit 6.10.27
- Updated Mazatrol viewer.
Changes since previous version:
CIMCO Edit 6.10.26
- Updated NC Assistant.
- Fixed problem using $USERNAME and $COMPUTERNAME in Macros/Machine configuration path.
CIMCO DNC-Max 6.10.26
- Added option to log MDC messages based on file contents of transferred files. Ref: Setup/Port/Configure Port/Transmit/Translators/Operation/ Log MDC Message Ref: Setup/Port/Configure Port/Receive/Translators/Operation/ Log MDC Message
- Added option to rename main program file when using the Siemens WPD split option. Ref: Setup/Port/Configure Port/Auto Receive/Set/ Associated Files/Rename main program file
- Added option to remove the extension from files when sending then using FTP in the directory monitor protocol. Ref: Setup/Port/Configure Port/Advanced/Other/Filename mode.
- Added option to use a reserved directory change program in the Heidenhain FE mode protocol that extracts the directory name using a trigger. Ref: Setup/Port/Configure Port/Advanced Settings/
- Extract directory name from reserved program
- Directory change trigger
- Reserved program
- Increased size of protocol configuration dialogs.
- Changed directory monitor WPD split to work without associated files enabled.
- Fixed problem sending programs in the Heidenhain FE mode for some TNC controls.
CIMCO MDC-Max 6.10.26
- Added option to set variables only in the Job/Program setup. Ref: Setup/System Setup/Job Setup/Set Job to field/Do not set Ref: Setup/System Setup/Program Setup/Set Job to field/Do not set
- Added option to set Job and Program to DATAVAR[1-8], DBVAR[1-4], program, job and operator. Useful when working with pallet machines. Ref: Setup/System Setup/Job Setup/Set Job to field/... Ref: Setup/System Setup/Program Setup/Set Job to field/...
- Fixed problem generating table/graphs summarizing all machines after creating a table/graph per machine.
CIMCO NC-Base 6.10.26
- Fixed problem associating file with multiple programs.
Changes since previous version:
CIMCO DNC-Max 6.10.25
- Added support for extracting comments from binary Mazak Smart files in the directory monitor protocol/NC-Base.
Changes since previous version:
CIMCO Edit 6.10.24
- Updated CNC-Calc.
- Fixed problem ignoring . or , in file compare. Introduced in 6.10.20.
Changes since previous version:
CIMCO Edit 6.10.23
- Updated backplot converters.
- Updated Mazatrol viewer.
CIMCO DNC-Max 6.10.23
- Added option to always create backups, even if the received file is identical to the latest backup. Ref: Setup/Port/Configure Port/.../Backup/Always backup
Changes since previous version:
CIMCO Edit 6.10.22
- Updated Mazatrol viewer.
CIMCO MDC-Max 6.10.22
- Fixed problem using live/operator screens. Introduced in 6.10.21.
Changes since previous version:
CIMCO Edit 6.10.21
- Added option to reload files from the tab right click menu.
- Changed reloading of files modified outside the editor to ignore deleted files.
- Updated backplot converters.
CIMCO DNC-Max 6.10.21
- Added option to automatically split auto received Siemens WPD files in the directory monitor protocol. Ref: Setup/Port/Configure Port/Auto Receive/Set/ Associated Files/Split Siemens .WPD files
- Added support for using $ONO5, $ONO7 and $ONO9 when renaming files.
Changes since previous version:
CIMCO Edit 6.10.20
- Fixed problem ignoring . or , after last digit when 'Ignore Numeric Format' was selected in the file compare configuration.
CIMCO MDC-Max 6.10.20
- Added support for using TEXT[xxx] in state names on live screens/operator screens.
Changes since previous version:
CIMCO MDC-Max 6.10.19
- Fixed problem generating reports after October 24th.
Changes since previous version:
CIMCO Edit 6.10.18
- Updated backplot.
CIMCO DNC-Max 6.10.18
- Fixed problem using multi file mode in the mazatrol protocol.
Changes since previous version:
CIMCO Edit 6.10.17
- Updated backplot.
Changes since previous version:
CIMCO Edit 6.10.16
- Updated Mazatrol viewer.
CIMCO DNC-Max 6.10.16
- Added support for using string translators on files in the FTP Server and directory monitor protocol. Ref: Setup/Port/Configure Port/FTP Server/Send Translators Ref: Setup/Port/Configure Port/FTP Server/Receive Translators Ref: Setup/Port/Configure Port/Directory Scan/Send Translators
- Fixed problem sending programs in the Heidenhain FE mode for some older TNC controls.
Changes since previous version:
CIMCO NC-Base 6.10.15
- Fixed problem exporting file list after searching file descriptions and contents.
Changes since previous version:
CIMCO DNC-Max 6.10.14
- Changed 'Add Port' dialog to show templates sorted.
- Fixed problem receiving some programs in the Heidenhain FE mode protocol.
- Fixed 'File not found' error when manually receiving Mazatrol file.
CIMCO MDC-Max 6.10.14
- Stripped # and ' from Excel variables.
Changes since previous version:
CIMCO MDC-Max 6.10.13
- Added option restrict access to operator screens using NC-Base logins/passwords Ref: Setup/System Setup/Operator Screens/Limit access to screen.
- Added option to map login to real names using NC-Base user table. Ref: Setup/System Setup/Operator Setup/Use real names from NC-Base
- Added option to increase button size on operator screens. Ref: Setup/System Setup/Operator Screens/Buttons/Button size
- Added support for mapping login pin/serial numbers to NC-Base user names.
Changes since previous version:
CIMCO Edit 6.10.12
- Updated Mazatrol viewer.
- Fixed problem generating toolpaths in CNC-Calc on some systems.
- Fixed toolpath statistics when using inch units.
CIMCO DNC-Max 6.10.12
- Added option to enable/disable file deletion in the FTP server protocol. Ref: Setup/Port/Configure Port/FTP Server/Allow file delete
- Fixed problem sending to some controls in Heidenhain FE mode.
CIMCO MDC-Max 6.10.12
- Added support for reading text values from Excel files. Values are stored in TEXT[EXCELVAR1] - TEXT[EXCELVAR4].
- Fixed problem updating live screens when 3rd party applications used port 4448 also.
- Fixed problem showing logon screen after pressing F11.
CIMCO NC-Base 6.10.12
- Added 'Yes to All' option when sending files.
- Fixed incorrect status names shown when prompting to change status.
- Fixed high database CPU utilization in some cases.
- Fixed problem specifying prefix/suffix for associated files.
- Fixed problem using 'Import Accept As'.
CIMCO Software 6.10.11 Released: 16-09-11
Changes since previous version:
CIMCO Edit 6.10.11
- Fixed backplot configuration for Mikron HSM 400U and Mikron HSM 600U.
CIMCO CNC-Calc 6.10.11
- Fixed problem setting some colors.
- Fixed crash.
CIMCO DNC-Max 6.10.11
- Added option to not create customers when receiving programs with an unknown customer name. Ref: Setup/Port/Configure Port/NC-Base/Do not create new customers
CIMCO NC-Base 6.10.11
- Fixed incorrect folder names for associated files when using customer folders.
- Fixed incorrect status names when using custom defined status texts.
CIMCO Software 6.10.10 Released: 14-09-11
Changes since previous version:
CIMCO CNC-Calc 6.10.10
- Added finishing toolpaths.
- Added turning stock limits.
- Improved turning support.
CIMCO DNC-Max 6.10.10
- Fixed crash when using barcode scanners with directory monitor protocols.
Changes since previous version:
CIMCO Edit 6.10.09
- Improved tool list display in the Mazatrol viewer.
- Fixed decimal problem for Mazak M2 in the Mazatrol viewer.
CIMCO CNC-Calc 6.10.09
- Fixed line/arc intersection problem.
CIMCO DNC-Max 6.10.09
- Fixed crash when sending large collection of Mazatrol files with long comments.
CIMCO MDC-Max 6.10.09
- Fixed port/group sorting in event log machine selection.
Changes since previous version:
CIMCO Edit 6.10.08
- Updated tool data support for Mazak M32 and M640M in the Mazatrol viewer.
CIMCO MDC-Max 6.10.08
- Increased maximum number of columns in tables from 20 to 100.
- Fixed problem printing timelines.
CIMCO NC-Base 6.10.08
- Changed import queue to show only auto imported or received files after accepting/rejecting imported program.
Changes since previous version:
CIMCO Edit 6.10.07
- Added support for locking the DNC configuration with the editor configuration password. Ref: Global Setup/Plugins/Configuration Password
CIMCO MDC-Max 6.10.07
- Added option to limit operator screens to specify machines for each client. Ref: Setup/System Setup/Client/ Limit operator screens to selected machines
CIMCO NC-Base 6.10.07
- Added name of machine that received file when searching the import queue.
- Fixed problem when searching import queue for files received by DNC or auto import.
Changes since previous version:
CIMCO NC-Base 6.10.06
- Fixed problem with missing buttons when running NC-Base in minimal mode.
Changes since previous version:
CIMCO MDC-Max 6.10.05
- Added support for operator sub-screens. Ref: Setup/System Setup/Operator Screens/Button/Show sub-screen
- Added option to lock full screen. Ref: Setup/System Setup/Lock full screen (F11 prompts for password)
CIMCO NC-Base 6.10.05
- Changed import queue only to show expanded list when a program has multiple files on the queue.
- Fixed problem rejecting program files when multiple imports existed for the same program in some cases.
Changes since previous version:
CIMCO DNC-Max 6.10.04
- Fixed problem using pin monitors in the barcode protocol for directory monitor machines.
CIMCO NC-Base 6.10.04
- Further reduced user interface when running NC-Base in super minimal mode.
Changes since previous version:
CIMCO NC-Base 6.10.03
- Fixed problem copying associated files in some cases.
Changes since previous version:
CIMCO Edit 6.10.02
- Fixed backplot display problem.
Changes since previous version:
CIMCO Edit 6.10.01
- Fixed problem showing multiple channel programs.
Changes since previous version:
CIMCO Edit 6.01.65
- Updated window title when viewing multiple channels in non-default order.
CIMCO NC-Base 6.01.65
- Improved performance when searching the import queue.
- Changed icon for new imported files on the import queue.
Changes since previous version:
CIMCO Edit 6.01.64
- Added option to specify the channel order when viewing multiple channels.
- Fixed problem displaying Mazatrol in Japanese.
- Fixed problem with picture name not copied when copying macros.
CIMCO MDC-Max 6.01.64
- Changed client to remember screen number/windows position.
Changes since previous version:
CIMCO DNC-Max 6.01.63
- Added support for exporting external logs to CSV files.
- Added support for configuring pin monitors in the barcode protocol.
CIMCO MDC-Max 6.01.63
- Fixed problem displaying timelines with only a single events.
CIMCO NC-Base 6.01.63
- Added confirmation prompt before saving files in the database.
Changes since previous version:
CIMCO Edit 6.01.62
- Fixed backplot tool scaling issue.
Changes since previous version:
CIMCO Edit 6.01.61
- Added option to copy macros.
CIMCO DNC-Max 6.01.61
- Fixed crash in the Mazak protocol when trying to remote requesting an ISO/EIA program using a Mazatrol Remote Request.
CIMCO MDC-Max 6.01.61
- Changed MDI tab close button to reset full screen mode when running operator screens in full screen.
- Fixed problem when starting operator terminals before network is ready.
Changes since previous version:
CIMCO Edit 6.01.60
- Added $FILENAMENOEXT to macro variables.
CIMCO DNC-Max 6.01.60
- Added support for controlling multiple machines from a single barcode port. Ref: Port/Handheld Terminals/Configure/Control multiple machines
- Fixed problem showing directory listings from "slow" network drives in the Heidenhain FE mode protocol.
CIMCO MDC-Max 6.01.60
- Added option to specify text size when selecting machine on operator screens. Ref: System Setup/Operator Screens/Machine list font size
- Added touch keyboard option for operator input values. Ref: System Setup/Operator Screens/Input Values/Show Keyboard
- Fixed problem saving the 'Multiple machines on one screen' option'.
- Fixed problem running full screen when showing job/data dialogs from operator screens.
- Fixed problem running full screen when using DNC-Max client from operator screens.
Changes since previous version:
CIMCO Edit 6.01.59
- Updated Mazatrol viewer.
- Added Emco Mill output for CNC Calc.
CIMCO DNC-Max 6.01.59
- Fixed problem using -c with DNCMaxCtrl.exe.
Changes since previous version:
CIMCO DNC-Max 6.01.58
- Fixed server crash when receiving files to the queue and the NC-Base debug option was enabled.
Changes since previous version:
CIMCO NC-Base 6.01.57
- Added support for specifying status names for 'Imported', 'Running In', 'Updating', 'Ready', 'Checked', 'Approved', 'Updated', 'Check failed' and 'Approval failed'. Ref: Database/Setup/Server Settings/Status Text
Changes since previous version:
CIMCO MDC-Max 6.01.56
- Increased maximum number of entries in log reports from 10.000 to 100.000.
Changes since previous version:
CIMCO NC-Base 6.01.55
- Fixed NC-Base performance issue. Introduced in 6.01.42.
Changes since previous version:
CIMCO DNC-Max 6.01.54
- Added additional Network I/O debug information.
Changes since previous version:
CIMCO DNC-Max 6.01.53
- Fixed problem automatically upgrading Hand Held Terminal configurations from V5.
CIMCO NC-Base 6.01.53
- Changed 'Copy Program' to make a copy of associated files stored in "field folders" or sub folders.
- Fixed problem with no backups created when replacing associated files using Drag'n'Drop in some cases.
Changes since previous version:
CIMCO Edit 6.01.52
- Added support for Siemens (WAITM) multi channel view.
- Added support for specifying a synchonization point ID trigger in the multi channel view.
CIMCO DNC-Max 6.01.52
- Fixed problem with Moxa I/O devices not connecting after connection was lost in some cases.
CIMCO NC-Base 6.01.52
- Changed NC-Base to move files to the program directory when changing the file type of an associated file to 'NC Data'.
Changes since previous version:
CIMCO Edit 6.01.51
- Updated backplot converters.
- Updated CNC-Calc.
CIMCO DNC-Max 6.01.51
- Added Moxa I/O debug log (Data\NetIODebug.log).
CIMCO MDC-Max 6.01.51
- Fixed problem with incorrect error message in configuration when using MSG[MONONLINE] and MSG[MONOFFLINE].
CIMCO NC-Base 6.01.51
- Changed auto import to keep existing name when importing setup sheet/ tool list/memo file, and a file of a different type with the same name existed.
- Fixed problem with import queue being cleared in some cases. (Introduced in 6.01.35).
- Fixed problem searching queue for users without accept/reject permissions.
- Fixed problem auto importing associated files when not importing the main program file.
Changes since previous version:
CIMCO Edit 6.01.50
- Updated backplot converters.
CIMCO MDC-Max 6.01.50
- Added support reading live screen info through socket.
CIMCO NC-Base 6.01.50
- Updated NC-Base converter.
Changes since previous version:
CIMCO Edit 6.01.49
- Updated CNC-Calc.
- Fixed problem showing backplot on some systems.
CIMCO NC-Base 6.01.49
- Fixed problem with some entries not shown in program log.
Changes since previous version:
CIMCO Edit 6.01.48
- Updated backplot converters.
CIMCO DNC-Max 6.01.48
- Fixed crash when receiving import existing NC-Base import.
Changes since previous version:
CIMCO Edit 6.01.47
- Updated CNC-Calc.
CIMCO DNC-Max 6.01.47
- Fixed problem with Log\$PORTNAME directory created on new installations.
CIMCO Software 6.01.46 Released: 19-04-11
Changes since previous version:
CIMCO Edit 6.01.46
- Updated backplot converters.
Changes since previous version:
CIMCO Edit 6.01.45
- Added setup icon to Editor toolbar.
- Updated backplot converters.
CIMCO DNC-Max 6.01.45
- Updated DNC-Max remote control application.
Changes since previous version:
CIMCO NC-Base 6.01.44
- Disabled support for previewing Word/Excel documents in the NC-Base preview window on systems with incompatible Word/Excel installations.
Changes since previous version:
CIMCO DNC-Max 6.01.43
- Fixed problem with the remote request 'Ignore NC-Base settings' option in the directory monitor protocol.
- Fixed problem with the remote request 'Ignore NC-Base locked status' option in the directory monitor protocol.
CIMCO MDC-Max 6.01.43
- Fixed problem printing some tables.
CIMCO NC-Base 6.01.43
- Fixed database high CPU problem. Introduced in 6.01.42.
Changes since previous version:
CIMCO Edit 6.01.42
- Updated CNC-Calc.
CIMCO DNC-Max 6.01.42
- Fixed problem using multi line bar-coded messages with the barcode protocol.
CIMCO NC-Base 6.01.42
- Fixed problem with log not showing changes for associated files that were linked to multiple programs.
Changes since previous version:
CIMCO Edit 6.01.41
- Updated Mazatrol viewer.
- Fixed R value displayed in the backplot when using diameter programming.
CIMCO NC-Base 6.01.41
- Fixed problem creating database temp directory when upgrading from V5.
Changes since previous version:
CIMCO Edit 6.01.40
- Added separate Emco milling and turning backplot converter.
- Added toolpath statistics button to the backplot toolbar.
- Added Y UP / Z Front configuration to the backplot setup.
CIMCO DNC-Max 6.01.40
- Added support for new Handyfile type in the Handyfile protocol.
CIMCO NC-Base 6.01.40
- Fixed problem deactivating 'Scan comments below toolname'.
Changes since previous version:
CIMCO Edit 6.01.39
- Added Emco backplot converter.
- Updated Mazatrol viewer.
Changes since previous version:
CIMCO Edit 6.01.38
- Updated CNC-Calc.
CIMCO NC-Base 6.01.38
- Fixed problem opening RTF files in an external editor.
Changes since previous version:
CIMCO Edit 6.01.37
- Updated backplot converters.
CIMCO NC-Base 6.01.37
- Fixed problem using MS SQL with NC-Base (introduced in 6.01.35).
Changes since previous version:
CIMCO Edit 6.01.36
- Fixed problem with files being closed when selecting NC-Base tab when ribbon bar was minimized.
CIMCO NC-Base 6.01.36
- Added support for previewing Word/Excel documents in the NC-Base preview window.
- Fixed problem with names of imported files not shown.
- Fixed problem setting the 'Add associated files to the import queue' option in some cases.
Changes since previous version:
CIMCO Edit 6.01.35
- Updated backplot.
CIMCO CNC-Calc 6.01.35
- Fixed problem with circular pockets.
CIMCO DNC-Max 6.01.35
- Fixed potential server crash when deleting ports.
CIMCO NC-Base 6.01.35
- Added option to place associated files on the import queue Ref: Database/Setup/Server Settings/ Add associated files to the import queue
Changes since previous version:
CIMCO Edit 6.01.34
- Updated Mazatrol viewer.
- Updated CNC-Calc.
CIMCO NC-Base 6.01.34
- Improved icons for files associated with external programs.
- Fixed problem deleting associated .pdf files.
Changes since previous version:
CIMCO DNC-Max 6.01.33
- Fixed problem using multiple FTP server protocol ports.
Changes since previous version:
CIMCO Edit 6.01.32
- Updated backplot converters.
CIMCO MDC-Max 6.01.32
- Fixed incorrect columns on operator job selection dialog.
CIMCO NC-Base 6.01.32
- Fixed problem deleting associated .pdf files.
- Fixed problem viewing PDF files. (Introduced in 6.01.31).
Changes since previous version:
CIMCO DNC-Max 6.01.31
- Added support for using the folder name as program name in the directory monitor protocol when using the 'Job Directories' option.
- Fixed problem with backups when using the directory monitor protocol with sub-folders and NC-Base.
CIMCO NC-Base 6.01.31
- Fixed problem replacing PDF files after previewing them in the NC-Base client.
Changes since previous version:
CIMCO DNC-Max 6.01.30
- Added entry to AutoImport.log when adding/updating associated files.
CIMCO NC-Base 6.01.30
- Added support for opening backups of associated documents (Word, PDF's etc.) from the Restore dialog.
Changes since previous version:
CIMCO Edit 6.01.29
- Backplot updated.
CIMCO DNC-Max 6.01.29
- Increased the maximum number of files on the transfer queue from 32 to 128.
- Fixed problem sending associated NC files from NC-Base in the standard serial protocol.
Changes since previous version:
CIMCO Edit 6.01.28
- Backplot updated.
CIMCO Software 6.01.27 Released: 25-02-11
Changes since previous version:
CIMCO Edit 6.01.27
- Backplot updated.
Changes since previous version:
CIMCO Edit 6.01.26
- Fixed problem with window title not always updating.
- Updated backplot radius compensation display.
Changes since previous version:
CIMCO Edit 6.01.25
- Updated backplot radius compensation display.
- Fixed problem showing NC-Assistant balloons when line numbers were enabled.
Changes since previous version:
CIMCO NC-Base 6.01.24
- Added port name to additional DNC log entries.
- Fixed problem with associated file updates not logged correctly in some cases.
- Fixed problem creating backups for associated files received by DNC-Max.
Changes since previous version:
CIMCO Edit 6.01.23
- Updated backplot converters.
CIMCO DNC-Max 6.01.23
- Changed 'Wait for XOn on lines matching' to end transfer when end of feed timeout is exceeded.
CIMCO NC-Base 6.01.23
- Added option to export transfer limit. Ref: Database/Setup/Server Settings/List Export/To File/Transfer Limit Ref: Database/Setup/Server Settings/List Export/To Printer/Transfer Limit
Changes since previous version:
CIMCO DNC-Max 6.01.22
- Added support in all protocols for using a barcode reader on a separate port for collecting monitoring messages.
- Fixed problem with monitor/barcode ports showing up in NC-Base and/or MDC-Max port list.
- Fixed problem with monitor/barcode ports creating directories in $MACHINE etc.
CIMCO MDC-Max 6.01.22
- Improved indicators on operator screens.
- Fixed problem with the live screen 'Hide Idle state' option.
Changes since previous version:
CIMCO Edit 6.01.21
- Added 'Find' buttons to the Backplot toolbar.
- Updated backplot radius compensation display.
- Fixed problem with macro graphics not moved when changing 'Type file path'.
CIMCO DNC-Max 6.01.21
- Added support for specifying multiple CNC IP addresses in the FTP server protocol.
- Added additional 'Alternate' logins in the FTP server protocol.
CIMCO NC-Base 6.01.21
- Added support for auto importing associated file with the same extension and prefix as the program name. Ref: Setup/Configure Server/NC-Base/Auto Import/Prg. Prefix
Changes since previous version:
CIMCO Edit 6.01.20
- Updated backplot converters.
Changes since previous version:
CIMCO Edit 6.01.19
- Fixed backplot problem.
Changes since previous version:
CIMCO Edit 6.01.18
- Updated backplot.
- Updated Mazatrol viewer.
CIMCO MDC-Max 6.01.18
- Added support for showing only machines with selected jobs/programs on timeline.
- Changed live timeline to show only updates for selected jobs/programs.
Changes since previous version:
CIMCO DNC-Max 6.01.17
- Fixed problem when auto receiving files with associated files configured but no associated files found.
CIMCO MDC-Max 6.01.17
- Added support for showing only selected jobs/programs on timelines.
CIMCO NC-Base 6.01.17
- Changed program status to 'Updated' when restoring a previous version.
Changes since previous version:
CIMCO DNC-Max 6.01.16
- Fixed FTP client connection problem.
CIMCO NC-Base 6.01.16
- Fixed problem when adding a new program from an existing program file using 'File Save As' and the filename was not changed.
Changes since previous version:
CIMCO Edit 6.01.15
- Updated translations.
CIMCO DNC-Max 6.01.15
- Fixed problem adding extensions in the FTP server protocol when the path contained '.'.
Changes since previous version:
CIMCO NC-Base 6.01.14
- Fixed problem deleting pre-defined fields.
- Fixed problem sorting programs. (introduced in 6.01.13)
Changes since previous version:
CIMCO Edit 6.01.13
- Improved toolpath statistics function.
- Updated backplot converters.
- Fixed problem reading some Mazatrol ISO files.
CIMCO DNC-Max 6.01.13
- Fixed problem reading some Mazatrol ISO files.
CIMCO NC-Base 6.01.13
- Fixed problem using custom SQL commands.
CIMCO Software 6.01.12 Released: 21-12-10
Changes since previous version:
CIMCO Edit 6.01.12
- Fixed problem selecting DNC port on the Transmission bar.
- Fixed crash when closing NC-Base file compare.
Changes since previous version:
CIMCO Edit 6.01.11
- Fixed crash when closing NC-Base file compare.
CIMCO CNC-Calc 6.01.11
- If no side cuts are taken the compensation type is always as selected.
Changes since previous version:
CIMCO Edit 6.01.10
- Added Upper case / Lower case functions.
- Added Mark/Delete range function.
- Updated Mazatrol viewer.
- Updated backplot converters.
- Fixed crash when selecting machine for DNC when advanced NC Functions was disabled.
CIMCO DNC-Max 6.01.10
- Fixed problem deleting hand held terminal configurations.
CIMCO MDC-Max 6.01.10
- Fixed problem setting TIMERLAST[] after a clear condition.
Changes since previous version:
CIMCO Edit 6.01.09
- Fixed problem using multi channel view of files with different types.
- Fixed problem using scroll wheel when backplot was open.
- Fixed problem saving empty lines when viewing files in multi channel mode.
Changes since previous version:
CIMCO Edit 6.01.08
- Changed line numbers to show actual line number when viewing multiple channels.
CIMCO MDC-Max 6.01.08
- Fixed problem printing tables on multiple pages.
Changes since previous version:
CIMCO Edit 6.01.07
- Added additional default multi channel configurations.
- Fixed crash when starting multi channel view when not configured correctly.
- Fixed problem synchronizing some file types.
- Fixed problem saving the 'Show line numbers' option.
CIMCO NC-Base 6.01.07
- Fixed problem searching programs when using MS SQL.
Changes since previous version:
CIMCO Edit 6.01.06
- Fixed multi line comment issue.
Changes since previous version:
CIMCO Edit 6.01.05
- Fixed line number issue.
Changes since previous version:
CIMCO Edit 6.01.04
- Added option to specify number of decimals used in backplot etc. Ref: Setup/File Types/Machine/Decimals
- Added current and total machining distance to the backplot status view.
- Added option to show line numbers. Ref: Setup/General/Editor/Show line numbers
- Improved file compare when comparing files with changes inside multi line comments.
- Fixed problem removing multi character block skips.
- Fixed problem adding block skips to lines containing ','
- Fixed problem renumbering Heidenhain files with multi line comments.
CIMCO DNC-Max 6.01.04
- Added support for starting/stopping port through the DNCMaxCtrl application.
- Fixed problem displaying Japanese in the DNC-Max server log.
CIMCO MDC-Max 6.01.04
- Fixed incorrect colors on graphs.
CIMCO NC-Base 6.01.04
- Added support for searching file descriptions and memos.
Changes since previous version:
CIMCO DNC-Max 6.01.03
- Added option to send files in ASCII mode when using the directory monitor protocols ftp client function. Ref: Setup/Port/Configure Port/Advanced Other/Send in ASCII mode
CIMCO NC-Base 6.01.03
- Added support for searching file names. Ref: Database/Setup/Client Settings/Search Settings/ Disable filename search
- Added support for searching the content of files. Ref: Database/Setup/Client Settings/Search Settings/ Disable file content search
- Removed save prompt when adding a modified program to the database.
Changes since previous version:
CIMCO Edit 6.01.02
- Added support for additional Fanuc style multi channel formats.
CIMCO DNC-Max 6.01.02
- Changed DNC-Max service manager to allow auto updating from V4/V5.
Changes since previous version:
CIMCO Edit 6.01.01
- Initial release. CIMCO Edit V5 History NOTICE: Valid maintenance is required to install this download!
CIMCO DNC-Max 6.01.01
- Initial release. NC-Base: 5.00.10 CIMCO DNC-Max V5 History NOTICE: Valid maintenance is required to install this download!